    • Product Features

      main information
      Product Series Modicon M221  
      product type Programmable Controllers  
      Rated power supply voltage [Us] 100...240 V AC  
      Discrete input quantity 9 Discrete input conforms to IEC 61131-2 Type 1  
      Number of analog inputs 2 at input range: 0...10 V  
      Solid state output type Relay normally open  
      Discrete output quantity 7 Relay  
      Discrete output voltage 5...125 Volt (V) DC
      5...250 Volt (V) AC
       
      Discrete output current 2 A  
      Additional information
      Discrete I/O number 16  
      Number of I/O expansion modules <= 4 suitable for transistor output
      <= 4 suitable for relay output
       
      Power supply voltage range 85...264 V  
      Network frequency 50/60 Hz  
      Instantaneous peak current <= 40 A  
      Power consumption VA <= 49 VA on 100...240 V maximum number of I/O expansion modules
      <= 33 VA on 100...240 V without I/O expansion modules
       
      Power output current 0.325 A on 5 V for expansion bus
      0.12 A on 24 V for expansion bus
       
      Discrete input logic Sink or source (positive/negative)  
      Discrete input voltage 24 V  
      Discrete input voltage type Direct current  
      Analog input resolution 10 bits  
      LSB value 10 mV  
      Conversion time 1 ms per channel + 1 controller cycle time for analog input  
      Permissible overload at the input +/- 30 V DC for analog input and 5 minutes maximum
      +/- 13 V DC for analog input constant
       
      Voltage state 1 guarantee >= 15 V applicable input  
      Voltage state 0 guarantee <= 5 V applicable input  
      Discrete input current 7 mA for discrete input
      5 mA for fast input
       
      input resistance 4.9 kOhm for fast input
      3.4 kOhm for discrete input
      100 kOhm for analog input
       
      Response time 10 ms open operation suitable for output
      35 µs close operation suitable input; I2...I5 terminal
      10 ms close operation suitable for output
      5 µs open operation suitable for fast input; I0, I1, I6, I7 terminal
      35 µs open operation suitable input; other terminals terminal
      5 µs off operation for fast input; I0, I1, I6, I7 terminal
      100 µs off operation for input; other terminals terminal
       
      Configurable filter time 0 ms for input
      12 ms for input
      3 ms for input
       
      Output voltage limit 125 V DC
      277 V AC
       
      Connection type-terminal connection 6 A on COM 1 termnal
      7 A on COM 0 termnal
       
      Absolute accuracy error +/- 1% of full scale for analog input  
      Electrical life Inductive load AC-15, (cos phi = 0.35) 240 V / 120 VA: 100000 times
      resistive (load) DC-12, 24 V / 48 W: 100000 times
      resistive (load) AC-12, 120 V / 240 VA: 100000 cycles of
      inductive load AC-15, (cos phi = 0.35) 240 V / 36 VA: 300,000 cycles of
      resistive (load) AC-12, 120 V / 80 VA: 300,000 cycles of
      inductive load (L/R = 7 ms ) DC-13, 24 V / 24 W: 100000 cycles
      resistive (load) DC-12, 24 V / 16 W: 300,000 cycles
      inductive (L/R = 7 ms) DC-13, 24 V / 7.2 W: 300,000 times
      inductive load AC-14, (cos phi = 0.7) 240 V / 240 VA: 100000 times
      inductive load AC-15, (cos phi = 0.35) 120 V / 60 VA: 100000 times
      inductive load AC-14, (cos phi = 0.7) 240 V / 72 VA: 300,000 times
      inductive load AC-15, (cos phi = 0.35) 120 V / 18 VA: 300,000 times
      resistive (load) AC-12, 240 V / 480 VA: 100000 times
      inductive Load AC-14, (cos phi = 0.7) 120 V / 120 VA: 100000 times
      Resistive (load) AC-12, 240 V / 160 VA: 300,000 times
      inductive load AC-14, (cos phi = 0.7) 120 V / 36 VA: 300,000 times
       
      operating frequency 20 switching operations/minute with maximum load  
      Mechanical life >= 20000000 times applicable relay output  
      Minimum load 1 mA at 5 V DC for relay output  
      Type of protection Unprotected on 5 A  
      Reset time 1 s  
      storage 256 kB for user application and data RAM and 10000 instructions
      256 kB for internal variables RAM
       
      data backup 256 kB built-in flash memory for backup of application and data  
      Data storage device 2 GB SD card optional  
      Battery Type BR2033 lithium non-rechargeable, battery life: 4 years  
      Cumulative running time 1 year at 25 °C by interrupting the power supply  
      1K instruction execution time 0.3 ms for events and periodic tasks  
      _ 0.2 µs Boolean  
      Execution time of each task 60 µs response time  
      Maximum target area size 512 %M memory bits
      8000 %MW memory words
      255 %C counters
      255 %TM timers
      512 %KW constant words
       
      Real Time Clock Have  
      Clock error <= 30 s/month at 25 °C  
      Control loop Adjustable PID regulator up to 14 synchronous cycles  
      Calculate the number of inputs 4 Fast input (high counting mode) (counting frequency: 100 kHz), counting capacity: 32 bits  
      Control signal type Single phase
      A/B
      pulse/direction
       
      Integrated connection type USB port with connector mini B USB 2.0
      Ethernet with connector RJ45
      non-isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
       
      power supply Serial The serial link is powered at 5 V 200 mA  
      Transfer rate 1.2...115.2 kbit/s (default 115.2 kbit/s) for bus length... 15 m-communication protocol: RS485
      1.2...115.2 kbit/s (default 115.2 kbit/s) for bus length... 3 m-Communication protocol: RS232
      480 Mbit/s-Communication protocol: USB
       
      Protocol USB port: USB protocol-SoMachine-Network
      non-isolated serial link: Modbus protocol master/slave-RTU/ASCII or SoMachine-Network
      : Ethernet protocol
       
      Ethernet port 10BASE-T/100BASE-TX 1 port and 100 m copper cable  
      Communication service Modbus TCP slave device
      DHCP client
      Ehternet/IP converter
      Modbus TCP server
      Modbus TCP client
       
      Local signal 1 LED green for accessible SD card (SD)
      1 LED red for BAT
      per channel 1 LED green for I/O status
      1 LED green for SL
      Ethernet network activity green for ACT
      Ethernet network connection yellow applicable link (link status)
      1 LED red applicable module error (ERR)
      1 LED green applicable PWR
      1 LED green applicable RUN
       
      Electrical connections Mini B USB 2.0 connector to a programming terminal terminal
      block, 3 terminals for connecting 24 V DC power
      connector, 4 terminals for analogue inputs
      Removable screw terminal for input and
      removable screw terminal for output
       
      cable length <= 10 m shielded cable for fast input
      <= 30 m unshielded cable for output
      <= 30 m unshielded cable for digital signal input
      <= 1 m unshielded cable for analog input
       
      isolation 2300 V AC between output and internal logic
      Non-insulated between analogue inputs
      500 V AC between
      input and internal logic Non-insulated between analogue inputs and internal logic
      1500 V AC between supply and ground
      500 V AC between sensor power supply and ground
      500 V AC between input and ground
      1500 V AC between output and ground
      2300 V AC between supply and internal logic
      500 V AC between sensor power supply and internal logic
      500 V AC between Ethernet terminal and internal logic
      2300 V AC between supply and sensor power supply
       
      Logo CE  
      Sensor power supply 24 V DC at 250 mA supplied by the controller  
      Installation method Top hat type TH35-15 Rail installation conforms to IEC 60715
      Top hat type TH35-7.5 Rail installation conforms to IEC 60715
      board or board with fixing kit
       
      high 90 mm  
      depth 70 mm  
      width 95 mm  
      product weight 0.346 kg  
      environment
      Standards compliant EN/IEC 60664-1
      EN/IEC 61131-2
      EN/IEC 61010-2-201
       
      certified product CSA
      cULus
      DNV-GL
      RCM
      IACS E10
      ABS
      LR
      EAC
       
      Environmental characteristics Ordinary and hazardous location  
      Anti-static discharge 4 kV contact in accordance with EN/IEC 61000-4-2
      8 kV in air in accordance with EN/IEC 61000-4-2
       
      Anti-electromagnetic domain 10 V/m (80 MHz...1 GHz) in accordance with EN/IEC 61000-4-3
      3 V/m (1.4 GHz-2 GHz) in accordance with EN/IEC 61000-4-3
      1 V/m (2.. .2.7 GHz) Conforms to EN/IEC 61000-4-3
       
      Withstand the magnetic field 30 A/m at 50...60 Hz conforming to EN/IEC 61000-4-8  
      Ability to resist instantaneous pulse 2 kV applicable power line conforms to EN/IEC 61000-4-4
      2 kV applicable relay output conforms to EN/IEC 61000-4-4
      1 kV applicable Ethernet line conforms to EN/IEC 61000-4-4
      1 kV applicable serial link conforms to EN /IEC 61000-4-4
      1 kV applicable E/S conforms to EN/IEC 61000-4-4
       
      Surge tolerance 2 kV applicable power line (AC) internal common mode conforms to EN/IEC 61000-4-5
      2 kV applicable relay output internal common mode conforms to EN/IEC 61000-4-5
      1 kV applicable E/S internal common mode conforms to EN/IEC 61000-4-5
      1 kV Applicable shielded cable internal common mode conforms to EN/IEC 61000-4-5
      0.5 kV Applicable power line (DC) Internal differential mode conforms to EN/IEC 61000-4-5
      1 kV Applicable power line (AC) Internal differential mode conforms to EN/IEC 61000-4-5
      1 kV Applicable relay output Internal differential mode conforms to EN/IEC 61000-4-5
      0.5 kV Applicable power line (DC) internal common mode conforms to EN/IEC 61000-4-5
       
      Conducted interference resistance 10 Vrms (0.15...80 MHz) conforms to EN/IEC 61000-4-6
      3 Vrms (0.1...80 MHz) conforms to marine specifications (LR, ABS, DNV, GL)
      10 Vrms (calibrated frequency (2, 3 , 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) in line with marine specifications (LR, ABS, DNV, GL)
       
      Electromagnetic radiation Conducted emission complies with EN/IEC 55011 power cord (AC), 0.15...0.5 MHz: 79 dBμV/m QP/66 dBμV/m AV
      conducted emission complies with EN/IEC 55011 power cord (AC), 0.5...300 MHz : 73 dBμV/m QP/60 dBμV/m AV
      conducted emission in accordance with EN/IEC 55011 power line, 10...150 kHz: 120...69 dBµV/m QP
      conducted emission in accordance with EN/IEC 55011 power line, 150 kHz ...1.5 MHz: 79...63 dBμV/m QP
      conducted emission in accordance with EN/IEC 55011 power cord, 1.5...30 MHz: 63 dBμV/m QP
      radiated emission in accordance with EN/IEC 55011 Class A 10 m, 30 ...230 MHz: 40 dBμV/m QP
      electromagnetic radiation in accordance with EN/IEC 55011 A 10 m, 200 MHz...1 GHz: 47 dBμV/m QP
       
      Resistance to instantaneous power failure 10 ms  
      Ambient temperature -10...55 °C for vertical installation
      -10...35 °C for vertical installation
       
      Storage temperature -25...70 °C  
      Relative humidity 10...95% during non-condensing operation
      10...95% during non-condensing storage
       
      IP protection level IP20 protective cover in place  
      Pollution level <= 2  
      Working altitude 0...2000 m  
      Storage height 0...3000 m  
      Anti-vibration 3.5 mm vibration frequency: 5...8.4 Hz) on the uniform rail
      1 gn vibration frequency: 8.4...150 Hz) on the uniform rail
      3.5 mm vibration frequency: 5...8.4 Hz) on the upper panel Installation
      1 gn Vibration frequency: 8.4...150 Hz) Installation on the upper panel
       
      Impact resistance 98 m/s² (Test waveform time: 11 ms)  
      Sustainability
      product type Green product certification mark (Green Premium) products  
      RoHS regulations (date code: YYWW) Conformity-Since 1415-Schneider Electric declaration of conformity   
      REACh regulations    
      Environmental compliance provide support  
      Recycling guide provide support  
    •  
         

     

    Cáp nguồn, cáp tín hiệu Siemens servo power line and signal line ​​​​​​​6FX5002-2DC10-1AB0 6FX5002-5CN01-1AB0 6FX5002-2CF02-1AB0 6FX5002-2DC00-1AB0
    Cáp nguồn, cáp tín hiệu Siemens servo power line and signal line ​​​​​​​6FX5002-2DC10-1AB0 6FX5002-5CN01-1AB0 6FX5002-2CF02-1AB0 6FX5002-2DC00-1AB0 Liên hệ
    Mô đun truyền thông  UTEK 6-port single-mode 2 optical 4 electrical industrial Ethernet switch 100M rail UT-62204SM/MM
    Mô đun truyền thông UTEK 6-port single-mode 2 optical 4 electrical industrial Ethernet switch 100M rail UT-62204SM/MM Liên hệ
    Mô đun truyền thông  UTEK industrial grade 1 optical 2 electrical switch fiber optic transceiver SC interface UT-60-D2T1SC
    Mô đun truyền thông UTEK industrial grade 1 optical 2 electrical switch fiber optic transceiver SC interface UT-60-D2T1SC Liên hệ
    Mô đun truyền thông  6-port single-mode 2 optical 4 electrical industrial Ethernet switch 100M rail UT-62204SM/MM
    Mô đun truyền thông 6-port single-mode 2 optical 4 electrical industrial Ethernet switch 100M rail UT-62204SM/MM Liên hệ
    Mô đun truyền thông UTEK 24-port rack-mounted 100M industrial Ethernet switch unmanaged UT-6524
    Mô đun truyền thông UTEK 24-port rack-mounted 100M industrial Ethernet switch unmanaged UT-6524 Liên hệ
    Mô đun truyền thông UTEK industrial-grade Ethernet switch 16-port rail-type network monitoring UT-6516
    Mô đun truyền thông UTEK industrial-grade Ethernet switch 16-port rail-type network monitoring UT-6516 Liên hệ
    Mô đun truyền thông UTEK 100M 8-port industrial Ethernet switch 100M rail-type unmanaged UT-6408
    Mô đun truyền thông UTEK 100M 8-port industrial Ethernet switch 100M rail-type unmanaged UT-6408 Liên hệ
    Mô đun truyền thông UTEK industrial grade 5-port 100M unmanaged Ethernet switch rail anti-static surge UT-6405SA
    Mô đun truyền thông UTEK industrial grade 5-port 100M unmanaged Ethernet switch rail anti-static surge UT-6405SA Liên hệ
    Mô đun truyền thông HI-TOP PROFIBUS DP master station communication management machine to MODBUS RTU/TCP slave station protocol converter gateway
    Mô đun truyền thông HI-TOP PROFIBUS DP master station communication management machine to MODBUS RTU/TCP slave station protocol converter gateway Liên hệ
    Mô đun truyền thông HI-TOP HI-TOP EtherNet/IP to Profinet protocol conversion gateway industrial grade HT3S-PNS-EIS
    Mô đun truyền thông HI-TOP HI-TOP EtherNet/IP to Profinet protocol conversion gateway industrial grade HT3S-PNS-EIS Liên hệ
    Mô đun truyền thông HI-TOP Profinet to EtherCAT gateway HT3S-PNS-ECS supports robot conversion to Siemens PLC
    Mô đun truyền thông HI-TOP Profinet to EtherCAT gateway HT3S-PNS-ECS supports robot conversion to Siemens PLC Liên hệ
    Mô đun truyền thông HI-TOP Modbus RTU/TCP to EtherCAT protocol converter gateway HT3S-ECS-MDN
    Mô đun truyền thông HI-TOP Modbus RTU/TCP to EtherCAT protocol converter gateway HT3S-ECS-MDN Liên hệ

     


    TÂN THÀNH CAM KẾT

    • Sản phẩm, hàng hóa chính hãng.
    • Giá cả cạnh tranh.
    • Dịch vụ chăm sóc khách hàng tận tâm.

    Thông Tin Công Ty

    Đã thông báo

     


    THÔNG TIN LIÊN HỆ:
    -------------------------------
    CÔNG TY TNHH THIẾT BỊ CÔNG NGHIỆP TTH
    Trụ sở: số 124 ngõ 79 Yên Hoà-Cầu giấy-HN
    Kinh doanh 1 : 0816.861.515
    Kinh doanh 2 : 0836.861.515
    Kinh doanh 3 : 0926.511.515
    Kinh doanh 4 : 0916.861.515
    Kinh doanh 5 : 0888.868.515
    Kinh doanh 6 : 0917.971.515
    Website: http://tanthanh-automation.com
    Website: http://thietbitudongtanthanh.com
    Website: http://diencongnghieptanthanh.com
    Email: tthkinhdoanh@gmail.com
    Email: tthkinhdoanh01@gmail.com

  • Kết nối với chúng tôi