The main technical parameters of the transmitter Technical Data Model Model | Working pressure Working pressure (MPa) | Value sender Switch setting (MPa) | Working temperature Temp.Range (°C) | Transmitter Power Power (V/A) |
CM-I | 32 | 0.1+0.05 0.2+0.05 0.35+0.05 0.45+0.05 0.6+0.05 0.8+0.05 1+0.05 | -20~+80 | - |
CS-III | ≤220/0.25 |
CS-IV |
CS-V |
CM |
CMS |
CMS-I |
CY-I | 1.6 |
CY-II |
YM-I | - |
CYB-I | 0.35+0.05 | DC24/2 |
ZS-I | -0.9 | -0.01~0.018 | ≤220V |
ZKF-II | -0.018 | DC24/2 |
- Origin: Mainland China
- Province: Zhejiang Province
- City: Wenzhou
- Color classification: CS-V (pressure difference) CS-III (pressure difference) CM-I (pressure difference visual inspection) HC (pressure gauge type) CYB-I (pressure gauge type) CY-II (pressure) CY-I (pressure ) YM-I (visual inspection of differential pressure) XC (vacuum gauge) ZKF-II (vacuum gauge) ZS-I (vacuum) CMS differential pressure mechatronics CS-III (differential pressure) 1/2 thread
Filter clogs the transmitter with contaminants
CY-I, CY-II and CYB type pressure transmitters are mainly used for oil return filters, and are also suitable for pressure monitoring of normal oil supply in hydraulic systems and thin oil lubrication systems. 1. The CY type pressure transmitter is generally installed in the oil inlet chamber of the oil return filter. When the hydraulic system is working, the pollutants in the oil are continuously intercepted by the filter element in the oil return cycle, so that the pressure of the oil inlet of the oil return filter gradually increases. When the pressure increases to the set value of the transmitter, the Transmitter action. And turn on the indicator light or buzzer alarm in the form of a switch, indicating that people should clean or replace the filter element in time or cut off the control circuit related to the hydraulic system in the form of a switch to ensure the normal operation of the hydraulic system. The connecting thread between the transmitter and the filter is M18x1.5. 2. YM—I type is a visual pressure transmitter. When the indicator mandrel at the upper end of the transmitter sticks out of the red circle, it indicates an alarm. After cleaning or replacing the filter element, the indicator mandrel automatically resets. The connecting thread of the transmitter is M18x1. .5. 3. CYB-I type is a pressure gauge type transmitter. When the normal return oil pressure reaches 0.35MPa, the pointer enters the red area to indicate that the filter element should be cleaned or replaced. The indicator light or buzzer can also be switched on to give an alarm. NOTE: It cannot be used with a computer.