download Google |
|
Product number | T3Z 068-22YR |
Product Code | 101087881 |
EAN number | 4030661057170 |
eCl@ss | 27-37-12-90 |
|
Certification |
|
Certification | USA/CAN CCC EAC |
|
Grading |
|
standard | EN ISO 13849-1 |
B10d normally closed contact (NC) | 100.000 |
Target time | 20 years |
note | |
|
General property |
|
product name | T3Z 068 |
standard | IEC 60947-5-1, IEC 60947-5-5, ISO 13850 |
raw material |
- raw materials for the outer casing | Cast iron, coloring |
- Cover material | Cast iron, coloring |
- Contact material | silver |
weight | 4540 g |
Emergency stop button (Y/N) | no |
|
Mechanical parameters |
|
Circuit connection description | Screw connection |
Cable cross section |
- Minimum cable cross section | 0,75 mm2 |
- Maximum cable cross section | 1.5 mm2 |
Mechanical life | 50000 operations |
note | All cable cross-section representations include wires and wire ears |
Power | Max. 50 N (the rope direction within 30 N) |
Indicator light (yes/no) | no |
Key reset (Y/N) | no |
Pull ring reset (Y/N) | Have |
Definitely disconnected angle | 32 ° |
Affirmative breaking torque | 18 Ncm |
Definitely disconnect the operating force | 50 N |
Wire length | Max. 2 x 50 m |
|
Ambient conditions |
|
Ambient temperature |
- Minimum ambient temperature | −30 °C |
- Maximum ambient temperature | +90 °C |
Protection level | IP65 according to IEC/EN 60529 |
|
Electrical parameters |
|
Conversion component description | Normally open contact (NO), open (NC) |
Conversion principle | Crawling circuit component |
Number of auxiliary contacts | 2 pieces |
Number of safe touch points | 2 pieces |
Rated impulse withstand voltage U imp | 4 kV |
Rated insulation voltage U i | 250 V |
Thermal test current I the | 10 A |
Application category | AC-15: 230 V / 2, 5 A, DC-13: 24 V / 6 A |
Maximum insurance capacity | 6 AD type glass insurance |
|
ATEX |
|
Gas explosion-proof category | no |
Dust explosion-proof category | no |
|
note |
|
At 3 m, the pull wire requires a support, see attachment |
|
Switch stroke diagram |
|
Pay attention to the switch stroke diagram contact closure contact open setting range breakpoint positive open sequence / angle VS NO contact adjustment range VÖ NC contact adjustable range N stroke |