| download Google |
| |
| Product number | T3Z 068-22YR |
| Product Code | 101087881 |
| EAN number | 4030661057170 |
| eCl@ss | 27-37-12-90 |
| |
| Certification |
| |
| Certification | USA/CAN CCC EAC |
| |
| Grading |
| |
| standard | EN ISO 13849-1 |
| B10d normally closed contact (NC) | 100.000 |
| Target time | 20 years |
| note | |
| |
| General property |
| |
| product name | T3Z 068 |
| standard | IEC 60947-5-1, IEC 60947-5-5, ISO 13850 |
| raw material |
| - raw materials for the outer casing | Cast iron, coloring |
| - Cover material | Cast iron, coloring |
| - Contact material | silver |
| weight | 4540 g |
| Emergency stop button (Y/N) | no |
| |
| Mechanical parameters |
| |
| Circuit connection description | Screw connection |
| Cable cross section |
| - Minimum cable cross section | 0,75 mm2 |
| - Maximum cable cross section | 1.5 mm2 |
| Mechanical life | 50000 operations |
| note | All cable cross-section representations include wires and wire ears |
| Power | Max. 50 N (the rope direction within 30 N) |
| Indicator light (yes/no) | no |
| Key reset (Y/N) | no |
| Pull ring reset (Y/N) | Have |
| Definitely disconnected angle | 32 ° |
| Affirmative breaking torque | 18 Ncm |
| Definitely disconnect the operating force | 50 N |
| Wire length | Max. 2 x 50 m |
| |
| Ambient conditions |
| |
| Ambient temperature |
| - Minimum ambient temperature | −30 °C |
| - Maximum ambient temperature | +90 °C |
| Protection level | IP65 according to IEC/EN 60529 |
| |
| Electrical parameters |
| |
| Conversion component description | Normally open contact (NO), open (NC) |
| Conversion principle | Crawling circuit component |
| Number of auxiliary contacts | 2 pieces |
| Number of safe touch points | 2 pieces |
| Rated impulse withstand voltage U imp | 4 kV |
| Rated insulation voltage U i | 250 V |
| Thermal test current I the | 10 A |
| Application category | AC-15: 230 V / 2, 5 A, DC-13: 24 V / 6 A |
| Maximum insurance capacity | 6 AD type glass insurance |
| |
| ATEX |
| |
| Gas explosion-proof category | no |
| Dust explosion-proof category | no |
| |
| note |
| |
| At 3 m, the pull wire requires a support, see attachment |
| |
| Switch stroke diagram |
| |
Pay attention to the switch stroke diagram contact closure contact open setting range breakpoint positive open sequence / angle VS NO contact adjustment range VÖ NC contact adjustable range N stroke |