Trang nhất
Thiết bị chống sét, kim thu sét
Kim chống sét, kim thu sét, satellite lightning rod ESE6000 , ESE5000 , ESE4000 , ESE2500
Đăng ngày 29-01-2019 06:05:16 AM - 648 Lượt xem
Mã sản phẩm: ESE6000 , ESE5000 , ESE4000 , ESE2500
Durmason type ESE5000 satellite lightning rod early discharge lightning rod
I. Introduction
ESE early discharge lightning rod is the leading lightning protection quality product in the world. It conforms to the international electrician (IEC) lightning protection specification and conforms to the national standard GB50057-94 "Building Lightning Protection Design Code". Installed and used 2 million sets in China to effectively implement lightning protection measures.
Second, the working principle
When the lightning cloud layer is formed, an electric field (atmosphere) is generated between the cloud layer and the ground, and the electric field strength can reach 5 kV / m. Thereby, corona discharge starts to appear on the raised portion of the floor or on the metal member.
When a downward pilot is formed inside the lightning cloud, lightning strikes begin. The downstream pilot charge moves to the ground in a stepped manner. The charge carried by the downstream pilot causes the ground to establish an electric field.
An upward leader is created from a building or object on the ground. This upstream direction is transmitted until it meets with the downstream leader. At this point, lightning current flows through the formed channel. Other buildings on the ground may generate several upstream pilots. The first upstream pilot that meets the down pilot determines the location of the lightning strike. The "satellite" brand early discharge lightning rod works by generating a faster upstream lead than an ordinary lightning rod.
Note: This description only describes the negative lightning strikes in the negative direction, which is the only application example of the electrical-geometric model. So far, such lightning strikes have occurred most often.
ESE2500, ESE4000, ESE5000, ESE6000 satellite lightning rod● "satelit+" early discharge lightning rod product model and protection radius. model | Early discharge time △T |
ESE2500 | 25 microseconds |
ESE4000 | 40 microseconds |
ESE5000 | 50 microseconds |
ESE6000 | 60 microseconds |
△T: According to the French international NFC17-102 regulation start preemption time, the actual test value is greater than the specified value "satelit+" lightning protection for different types of installation heights for different types of lightning protection buildings (Rp) |
"satelit+" tip height | h = higher than the level of the protected object (m) |
2 | 4 | 5 | 7 | 10 | 15 | 30 | 45 | 60 |
The first type of lightning protection building (rolling ball radius 30m) |
ESE2500 | 19 | 39 | 49 | 50 | 51 | 53 | 55 | - | - |
ESE4000 | 26 | 52 | 65 | 66 | 67 | 68 | 70 | - | - |
ESE5000 | 30 | 60 | 76 | 77 | 77 | 78 | 80 | - | - |
ESE6000 | 35 | 69 | 86 | 87 | 88 | 89 | 90 | - | - |
Lightning lightning rod in advance, the second type of lightning protection building (rolling ball radius 45m) |
ESE2500 | twenty three | 45 | 57 | 59 | 61 | 63 | 68 | 70 | - |
ESE4000 | 30 | 60 | 75 | 76 | 77 | 80 | 84 | 85 | - |
ESE5000 | 35 | 69 | 86 | 87 | 88 | 90 | 94 | 95 | - |
ESE6000 | 40 | 78 | 97 | 98 | 99 | 101 | 104 | 105 | - |
The third type of lightning protection building (rolling ball radius 60m) |
ESE2500 | 26 | 52 | 65 | 66 | 69 | 72 | 79 | 84 | 85 |
ESE4000 | 33 | 66 | 84 | 85 | 87 | 89 | 95 | 99 | 100 |
ESE5000 | 38 | 76 | 95 | 96 | 98 | 100 | 106 | 110 | 110 |
ESE6000 | 44 | 87 | 107 | 108 | 109 | 111 | 116 | 120 | 120 |
-
-
MTL safety barrier MTL5081 MTL5581 MTL5082 MTL5031 ICC212 SLP32D
Liên hệ
-
-
Eaton MTL Surge Protector IOP32 IOP32D ICC212Inquiry ICC312 Inquiry TP48-N-NDIInquiry IOP-HC32 SLP32D TP48-3-I-NDI SD32T3 SD32MXL
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AM3-20/1+NPE-S AM3-20/2-S AM2-40/1+NPE-S AM2-40/2-S AM2-40/3+NPE-S AM3-20/3+NPE-S
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector FLD3-20/4 FLD3-20/3+NPE
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AM3-20/4 AM3-20/3+NPE AM3-20/2 AM3-20/1+NPE AM3-05D-220 AM3-20/3+NPE-S
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AM3-20/2 AM3-20/1+NPE AM3-20/4 AM3-20/3+NPE AM3-05D-220 AM3-20/3+NPE-S
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AM-48DC (Single Mode) AM-48DC/2(2p)
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AM3-20/3+NPE AM3-20/4 AM3-20/2 AM3-20/1+NPE
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AD-L20-385-4 AD-L40-385-4 AD-L20-385-mini AD-L20-385-2 AD-L40-385-2
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AM3-20/4-S AM3-20/3+NPE-S AM2-40/4-S AM2-40/3+NPE-S AM2-40/1+NPE-S AM1-80/3+NPE-S AM2-40/2-S AM1-80/4-S AM3-20/2-S
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AD-L20-385-4 AD-L40-385-4 AD-L20-385-mini AD-L20-385-2 AD-L40-385-2
Liên hệ
-
-
Thiết bị chống sét, ASP surge protector AM2-40/2 AM2-40/1+NPE AM3-05D-220 AM2-40/1+NPE-S
Liên hệ