Full name | Power amplifier for flow pressure control valve |
English Translation | Power Amplifiers For Pressure & Flow Control Valves |
| |
model | PF-DC-24 |
| |
parameter | Power supply: DC (direct current) 24/48V |
| Maximum output power: 24/48W |
| Maximum output current: 1050MA |
| Response speed: 0.2-5s |
| Load impedance: 10/40 ohms (when the load is 40 ohms, the input voltage can only be 48V, and it can only be connected between F(DC+) and GND) |
| Control signal input: 0~10VDC |
| FUSE: 3A/250V |
| Flutter frequency: 0-500HZ |
| Ambient temperature: 0~65℃ |
| Temperature drift (maximum): 0.3mA/C |
| |
Applicable control | Control all direct-acting and pilot-operated, overflow-type proportional pressure flow valves without electrical position feedback. It has a ramp generator, which can separately adjust the rise and fall time, and can also set the upper/lower current limit. The power supply has wrong pole protection function. The products are all made by SMD patch technology, small size, strong anti-interference, good quality and low price. |
| |
English description of terminal | P(DC+) ─Pressure input power DC24V |
| F(DC+) ─ Flow input power DC24V or DC48V |
P=pressure | GND - input power common |
F=Flow | P+ ─Pressure valve positive |
DC=DC | P- ─ negative pressure valve |
| F+ ─Flow valve positive |
| F- ─Flow valve negative |
| 12V ─ auxiliary power supply for variable resistance |
| GND-control common point |
| P(vin) ─ Pressure input signal point |
| F(vin) ─ Flow input signal point |
| |
Definition of potentiometer on circuit board | P(MAX) ─ Maximum pressure adjustment |
| P(MIN)-minimum pressure adjustment ( adjusted at the factory, no need to adjust) |
| P(UP) ─ Pressure ramp-up time (factory adjusted to the minimum value) |
| P(DOWN)─Pressure ramp down time (factory adjusted to minimum value) |
| F(UP) ─ Flow ramp-up time (factory adjusted to minimum value) |
| F(DOWN)─Flow ramp down time (factory adjusted to the minimum value) |
| F(MAX) ─ Maximum flow adjustment |
| F(MIN) ─ The adjustment of the minimum flow rate (the factory has been adjusted, no need to adjust) |