product description
Tedia single point load cell
1022
characteristic
●Measuring range: 3-200kg
●The height is only 22mm
●Aluminum structure
●Single point 350x 350mm weighing pan size
●IP66 protection level
●OIML R60 and NTEP certification
optional features
●EEx ia IIC T4-ATEX explosion-proof certification ●FM certification
●Symmetric structure optional
describe
The 1022 is a single point sensor designed for low cost weighing scales. Its compact form factor and low cost are suitable for retail scales, pricing scales and counting scales.
The range from 3 to 200kg has obtained OIML R60 (4000d) or NTEP (5000d, single) certification, and the protection level can reach IP66. ATEX EEX iaIIC T4 certified for hazardous environments.
application
●Flat scale
●counting scale
●Retail scales
Technical ParametersTedia 1022 aluminum single point sensor
SPECIFICATIONS |
PARAMETER _ | Value VALUE | Unit UNIT |
Rated range Standard capacities (E max ) | 3, 5, 7, 10, 15, 20, 30, 35, 50, 100, 150, 200*** | kg |
NTEP/OIML accuracy class | NTEP | Non-Approved | C3* | C4 | |
Number of subdivisions | 5000 single** | 1000 | 3000 | 4000 | |
Y = E max /V min | 10000 | 1400 | 6000 | 10000 | Maximum available 12000 |
Rated output | 2.0 | mV/V |
Rated output tolerance | 0.2 | ±mV/V |
zero balance | 0.2 | ±mV/V |
Zero point reply ( 30 minutes ) | 0.0330 | 0.0300 | 0.0170 | 0.0125 | ±% of applied load |
Comprehensive error | 0.0200 | 0.0500 | 0.0200 | 0.0150 | ±% of rated output |
Zero temperature influence coefficient | 0.0023 | 0.0100 | 0.0023 | 0.0014 | ±% of rated output/°C |
Sensitivity Temperature Influence Coefficient | 0.0010 | 0.0030 | 0.0010 | 0.00075 | ±% of rated output/°C |
Four Corner Error | 0.0057 | 0.0085 | 0.0057 | 0.0042 | ±% of rated load/cm |
Temperature Compensation Range | –10 to +40 | °C |
range of working temperature | –20 to +70 | °C |
Maximum overload capacity | 150 | % of RC |
Ultimate overload capacity | 300 | % of RC |
Recommended excitation voltage Excitation, recommended | 10 | VDC or VAC RMS |
Excitation voltage , maximum | <15 | VDC or VAC RMS |
Input impedanceInput impedance | 415±15 | Ω |
Output impedance Output impedance | 350±3 | Ω |
Insulation resistanceInsulation resistance | >2000 | MΩ |
wire length | 0.5 | m |
Wire form | 4 wire, PVC, single floating screen | Standard |
MaterialConstruction _ | Aluminum | |
Protection classEnvironmental protection | IP66 | |
Support table size | 350 x 350 | mm |
Tightening torque | Up to 30 kg: 7.0 35 kg and up: 10.0 | N*m |
*50% Utilization
**50% Utilization
***150–200 kg without NTEP certification, 200 kg without OIML certification
Installation Dimensions