Transcell CD load cell features:
Transpower CD load cell; digital sensor (optional); output RS-485 standard signal (optional); all stainless steel structure; all welded seal; easy to install, fast; high precision; Stability; suitable for laboratory machines, truck scales and large hopper scales, etc.
● Column sensor
● Digital sensor (optional)
● Output RS-485 standard signal (optional)
● All stainless steel structure
● All welded seal
● Easy and fast installation
● High precision
● High stability
● Suitable for
measuring ranges such as experimental machines, truck scales and large hopper scales
● 10t, 20t, 30t, 50t
parameter
Rated Output | Rated output | 2.0mV/V ±0.1% |
Zero Balance | Zero balance | ±0.1% of rated output |
Creep after 30 minutes | Creep | ±0.03% of rated output |
Nonlinearity | Nonlinear | ±0.03% of rated output |
Hysteresis | Lag | ±0.03% of rated output |
Repeatability | Repeatability | ±0.03% of rated output |
Temp. effect on output | Sensitivity temperature drift | ≤0.002% of applied output/oC |
Temp. effect on zero | Zero temperature drift | ≤0.002% of rated output/oC |
Safe Temp. Range | Available temperature range | -10oC to + 70oC |
Temp. Compensated | Temperature compensation range | -10oC to + 40oC |
Safe Overload | Safety load | 150% |
Input Impedance | input resistance | 387 ohm ± 20 ohm |
Output Impedance | Output impedance | 350 ohm ± 5 ohm |
Insulation Resistance | Insulation resistance | ≥5000 M ohm (50V DC) |
Rated Excitation | Recommended excitation voltage | 10V DC/AC |
Maximum Excitation | Maximum excitation voltage | 15V DC/AC |
Cable Length | Wire length | 6m |
Cable Color Code | Wire color | Red(+E) Black(-E) Green(+S) White(-S) |