Applicable environment
1. It is recommended to use a single sensor or match with multiple sensors after passing through the junction box
2. Install on the spot near the sensor
3. The on-site working environment is relatively harsh, and the protection level IP68 can be customized for special requirements
Features
●Cast aluminum shell, waterproof design, good sealing, suitable for various harsh environments
●Built-in 24-bit high-precision AD converter
● Multi-segment linear calibration function●Configurable software filtering algorithm●Three-terminal isolation of power supply, sensor input and communication interface, strong anti-interference ability●Standard MODBUS RTU license agreement●Convenient and quick module address setting●Can be connected to various strain bridge sensors such as weighing, tension, pressure, torque, etc.Product Description
shell material | Cast aluminum |
net weight | 460g |
Performance
Load capacity | 6 350Ω sensors in parallel |
Applicable sensitivity | 0.3~2.0mV/V (customizable) |
input signal | mV signal |
output signal | RS485, switch or transmission output optional* |
Protocol | ModBus RTU |
Internal code resolution | >1000000 |
Precision | 0.1/0.05% ± 2digit |
Temperature Coefficient | Better than 1 0 0ppm |
powered by | (9~26) VDC |
Applicable sensor excitation voltage | (5~12) VDC |
* Indicates that the corresponding expansion card is required to realize this function
Environmental parameters
Operating temperature | -30~85℃/85%RH |
Installation method | Fixed foot installation |