Overview
LD-B10-220 series dry-type transformer temperature controller (referred to as temperature controller) is an intelligent controller designed for the safe operation of dry-type transformers. The thermostat adopts single-chip technology, and uses three platinum thermal resistors embedded in the three-phase winding of the dry-type transformer to detect and display the temperature rise of the transformer winding, and can automatically start and stop the cooling fan to perform forced air cooling on the winding, and can Control over temperature alarm and over temperature trip output to ensure that the transformer is running in a safe state.
2, function and model classification Model | Features |
LD-B10-220D type | Three-phase patrol measurement; three-phase patrol display/maximum display and two functions switching; input open circuit and fault self-test display and output; cooling fan automatic start and stop output; over-temperature alarm display and output; over-temperature trip display and output ; Fan manual / automatic control two status display, output and switch; each channel display value digital compensation; "black box" function; fan timing start and stop control function; output status detection. |
LD-B10- 220 E type | B10-with-the LD 220D , additions three independent 4 ~ 20mA analog current output. |
LD-B10- 220 F type | B10-with-the LD 220D , additions RS-485/232 serial communication. |
LD-B10- 220 G type | B10-with-the LD 220D type, all the way to increase room temperature measurement and control. |
LD-B10- 220 Type I | B10-with-the LD 220D type transformer core all the way to increase the temperature measurement and alarm. |
Note: If the user has other special technical requirements for the thermostat, please explain when ordering. 3. Technical index 3.1 Measurement range: -30.0°C~240.0°C 3.2 Measurement accuracy: Accuracy class Level 1 (temperature controller 0.5 level, sensor class B) resolution 0.1°C 3.3 Conditions of use: Ambient temperature -20°C~+55°C Relative humidity < 95% (25 ° C) power supply voltage AC220V (+10%, -15%) power supply frequency 50Hz or 60Hz (± 2Hz) 3.4 Thermostat power consumption: ≤ 8W 3.5 Implementation standards: Production standards: JB/T7631- 2005 "Electronic Temperature Controller for Transformers" passed the certification: ISO9001:2008 International Quality Management System Certification passed the test: IEC61000-4:2002 International Standard GB/T17626-2008 "Electromagnetic Compatibility Test and Measurement Technology" Standard 3.6 Relay contacts Output: Fan contact capacity: 10A/250VAC control output capacity: 5A/250VAC; 5A/30VDC (resistive) 3.7 Pt100 sensor leads are three-wire system, the probe size: Ф3mm×30mm or Ф4mm×40mm 3.8 Thermostat Dimensions: 320mm × 260mm × 80mm (height × width × thickness) Opening size: 280mm × 160mm (height × width)