| Function | illustrate |
| power supply | AC 85V ~ 265V, 50/60Hz, about 8W DC 18V ~ 36V, about 8W (optional) |
| Inductor excitation voltage | DC10V±5% current 150mA, up to four 350Ω sensors can be connected |
| small sensitivity | 0.25μV/d |
| Zero adjustment range | -30.5mV ~ +30.5mV |
| Measuring voltage range | -30.5mV ~ +30.5mV |
| temperature range | ≤ (0.0008% of reading+0.3d )/℃ |
| range stability | 8ppm/k of reading |
| nonlinear error | ≤ 0.005%FS |
| internal resolution | 520,000 |
| display accuracy | 1/50,000 |
| Sampling speed | 200 times/sec |
| Sampling method | Delta-Sigma |
| display element | Six-digit 0.56-inch, red seven-section code high-brightness LED display |
| LED display | Gross, Net, Stable, Zeroed, Kg/lb, Ton |
| button | MODE mode, TRAE tare/increment, GR/NT gross weight/net weight, ZERO zero point |
| Adapt to the environment | Temperature: -10°C ~ +45°C |
| | Humidity: 20% ~ 80% |
| weight | About 0.65kg |
| Panel cutout size | 92.5(W)×46(H)mm |