Three-phase multi-function digital display technical indicators:
1. Nominal signal input: AC 1A, 5A
Overrange: Instant: 10 times/5 seconds; Continuous: 1.2 times
2. Measurement range: 0~6A, input directly or through the transformer
3. Display range: 0.000~9999 A, KA, the decimal point is automatically switched according to the range
4. Accuracy: 0.5%
5. Insulation strength: IEC 60255-5 2KVrms-1min
6. Environmental tolerance: Working IEC 60068-1 and 20 °C ~ +55 °C
Store IEC 60068-1 and 2 -25 ° C ~ +70 ° C
Wet heat IEC 60068-1-3 93%RH 40°C
7. Use occasions: no corrosive gas and metal dust, altitude < 3000 m
8. Working power and power consumption: AC (85~265)V or DC (100~275)V ≤5VA
2 considerations
1. Before use, the meter needs to be powered for 15 minutes.
2, pay attention to prevent vibration and shock, do not use in places with excessive dust and excessive harmful gases.
3. The input wire should not be too long. If the input end of the signal to be tested is long, please try the twisted pair shielded wire.
4. If the signal is accompanied by high frequency interference, the low frequency filter should be tested online.
5. When not storing for a long time, please power on every three months for not less than 4 hours.
6, long-term preservation should avoid direct light, should be stored in the ambient temperature -25 ° C ~ 55 ° C.
7. If the meter has no display, check the auxiliary power supply first, and the voltage is within the range.
8. If the display is not normal, check if the input signal is normal and the signal terminal is tight.
9. Unless the PT has sufficient power, the PT signal cannot be used as an auxiliary power source at the same time to ensure the normal operation of the meter.
10. The current terminal screw in the CT circuit must be tightened to ensure reliable contact between the incoming and outgoing wires to avoid malfunction.
11. If the instrument is to be calibrated, the calibration instrument should be better than 0.1 to ensure the calibration accuracy.
3 standard configuration
(1) The meter measures the three-phase current on the grid. Digital zero calibration, digital calibration, high precision and high cost performance.
(2) Standard CT input.
(3) Wide range AC/DC universal power supply AC/DC80-265V or AC 220V.
(4) Three rows of four LED digital real-time display, the meter can set the display value through the display panel buttons.