Trang nhất
Thiết bị ngành xi măng, thép, nhiệt điện
Công tắc áp suất CS-V 0.35MPa
Đăng ngày 20-09-2018 01:43:03 PM - 763 Lượt xem
Mã sản phẩm: CS-V 0.35MPa
1. The CS type and CS-IV type transmitters block the oil filter clogging alarm in the form of a switch, or cut off the control circuit related to the hydraulic system in the form of a switch, thereby protecting the safety of the system.
The connection thread of the CS-III type differential pressure transmitter is M22X1.5.
The connection size of the CM type differential pressure transmitter is the same as that of the CS-II and CS-V types, and can be used for domestic ZU type and XU type filters.
The CMS type differential pressure transmitter is similar to the CM type with visual indication, CS-V and CMS type, but no visual indication.
2, CM-I type is the visual differential pressure transmitter, the red indicator button at the upper end of the transmitter highlights the action of the transmitter and has alarmed. When cleaning or replacing the filter element, the red indicator button of the transmitter should be manually Reset, the connector thread of the transmitter is M22X1.5.
The CMS type transmitter combines the power transmission with the target transmission, enabling both power transmission and target transmission. It combines electric transmission with visual communication to enable both electric and visual alarms. When the filter element is cleaned or replaced, the red indicator button of the transmitter is automatically reset.
If the electrical signal cannot be alarmed due to a fault in the electrical component or the line, the other end can also send an alarm to accurately alarm, thus improving the reliability of the transmitter.
When the hydraulic system is working, the filter element in the oil filter is blocked by the pollutant, and the pressure of the inlet and outlet generates a pressure difference. When the pressure difference increases to the set value of the transmitter, the switch of the transmitter is turned on and the signal is alarmed. At the same time, the other end of the message shows that the red button of the transmitter pops up to indicate an alarm, indicating that the system operator should clean or replace the filter element in time to ensure the normal operation of the hydraulic system.
The basic function of the differential pressure signaling device is that during the working process of the hydraulic system, the impurity particles in the oil are blocked by the filter element in the oil filter, so that the filter element is gradually blocked, and the pressure difference between the inlet and outlet ports (ie, pressure loss) is generated. When the differential pressure value reaches 0.35Mpa, the power is automatically turned on to display the signal.
The main technical parameters of the transmitter Technical Data Model Model | Working pressure Working pressure (MPa) | Value sender Switch setting (MPa) | Working temperature Temp.Range (°C) | Transmitter Power Power (V/A) |
CM-I | 32 | 0.1+0.05 0.2+0.05 0.35+0.05 0.45+0.05 0.6+0.05 0.8+0.05 1+0.05 | -20~+80 | - |
CS-III | ≤220/0.25 |
CS-IV |
CS-V |
CM |
CMS |
CMS-I |
CY-I | 1.6 |
CY-II |
YM-I | - |
CYB-I | 0.35+0.05 | DC24/2 |
ZS-I | -0.9 | -0.01~0.018 | ≤220V |
ZKF-II | -0.018 | DC24/2 |