Measuring medium
Measuring range of various liquids, gases or vapors compatible with 304, 316 or 316L stainless steel Table pressure 0~0.01MPa to 0~60MPa Absolute pressure 0~0.1MPa to 0~60MPa Vacuum 0~-0.1MPa
Overload pressure 1.5 times Full-scale (take smaller value)
output signal 4~20mADC (two-wire system) 0~10VDC, 0~5VDC, l~5VDC (three-wire system)
supply voltage 9~36VDC (two-wire system), 24±5VDC (three-wire system) )
medium temperature -30 ~ + 85 ℃
ambient temperature of -20 ~ + 85 ℃
storage temperature -40 ~ + 90 ℃
relative humidity of ≤ 95% (40 ℃)
rise time ≤5 milliseconds up to 90% FS
accuracy 1.0, 0.5 Level, 0.25 (comprehensive error including nonlinearity, repeatability and hysteresis)
Zero adjustment ±8% of the
range of the output range ±20% of the output range
Temperature drift ≤±0.05%FS/°C (temperature range -20~ 85°C, including temperature effects at zero and span)
Temperature compensation range 0 to 70°C
Stability Typical: ±0.1%FS/year Maximum: ±0.2%FS/year
Medium contact material 304, 316 or 316L
Housing material 304 or 316 stainless steel
Installation method Thread mounting
pressure connection
Electrical connection such as M20×1.5, M12×l, Gl/4, Gl/2 male thread Four-core shielded cable (degree of protection IP65) aviation plug DIN connector