The basic features of the VICTOR 11+ process calibrator : measurement and output accuracy of 0.02%, measurement display of 5 bits, output display of 6 bits
VICTOR 11+ process calibrator measurement function: DC voltage, DC current, frequency, on-off measurement, pressure
Basic features of the VICTOR 11+ process calibrator :
1 output basic accuracy of 0.02%, output display is 6 bits
2 output functions: DC voltage, DC current, ohms, analog transmitter, thermocouple, RTD, frequency, pulse, switching
. 3 DC current output, may provide 25% and 100% of the stepping manual, automatic and automatic stepping ramp output
4 thermocouple output, high precision automatic cold junction compensation, °C or °F temperature display
5 can be equipped with high-precision temperature probe, accuracy: ± 0.2 ° C
6 large-screen LCD multi-data display, can display simultaneously: DC current and % value, thermocouple, thermal resistance temperature value and its corresponding division value, etc.
7 , excellent operating performance keyboard configuration, display the set value corresponding to a bit and down keys set the LCD output
8 Panel calibration technology allows calibration without opening the case
9 with white LED backlight, with automatic backlight off and automatic power off function, suitable for field use
VICTOR 11+ process calibrator output basic technical indicators
[ Applicable for one year after calibration, 23 °C ±5 °C , 35 to 70% RH , accuracy = ± (set value % + range % ) ]
Features | Range | Output setting range | Resolution | Accuracy | Remarks |
DC voltage DCV | 100mV | -10.000 to 110.000mV | 1 μV | 0.02+0.01 | Maximum output current 0.5mA |
1000mV | -100.00 to 1100.00mV | 10 μV | 0.02+0.01 | Maximum output current 2mA |
10V | -1.0000 ~ 11.0000V | 0.1mV | 0.02+0.01 | Maximum output current 5mA |
DC current DCmA | 20mA | 0.000 ~ 22.000mA | 1 μA | 0.02+0.02 | External power supply 5 to 28V at 20 mA , maximum load 1KΩ resistor analog transmitter |
Ohm OHM | 400 Ω | 0.00 Ω to 400.00 Ω | 0.01 Ω | 0.02+0.02 | Current is ±0.5~3mA When the current is ±0.1~0.5mA , add 0.1Ω additional error Lead resistance is not included in the accuracy |
4K Ω | 0.0000K Ω~ 4.0000KΩ | 0.1 Ω | 0.05+0.025 | Current is ±0.05~0.3mA Lead resistance is not included in the accuracy |
40K Ω | 0.000K Ω to 40.000KΩ | 1 Ω | 0.1+0.1 | Current is ±0.01mA Lead resistance is not included in the accuracy |
Thermocouple TC | R | 0 °C to 1767 °C | 1 °C | 0 to 100 °C : 1.5 °C 100 to 1767 °C : 1.2 °C | Adopt ITS-90 temperature scale Accuracy does not include cold junction compensation error |
S | 0 °C to 1767 °C | 0 to 100 °C : 1.5 °C 100 to 1767 °C : 1.2 °C |
K | -200.0 °C to 1372.0 °C | 0.1 °C | -200.0 ~-100.0 °C : 0.6 °C -100.0 to 400.0 °C : 0.5 °C 400.0 ~ 1200.0 °C : 0.7 °C 1200.0 ~ 1372.0 °C : 0.9 °C |
E | -200.0 °C ~ 1000.0 °C | -200.0 ~-100.0 °C : 0.6 °C -100.0 ~ 600.0 °C : 0.5 °C 600.0 ~ 1000.0 °C : 0.4 °C |
J | -200.0 °C ~ 1200.0 °C | -200.0 ~ -100.0:0.6°C -100.0 to 800.0 °C : 0.5 °C 800.0 ~ 1200.0 °C : 0.7 °C |
T | -250.0 °C ~ 400.0 °C | -250.0 to 400.0 °C : 0.6 °C |
N | -200.0 °C ~ 1300.0 °C | -200.0 ~-100.0 °C : 1.0 °C -100.0 to 900.0 °C : 0.7 °C 900.0 ~ 1300.0 °C : 0.8 °C |
B | 600 °C ~ 1820 °C | 1 °C | 600 ~ 800 °C : 1.5 °C 800 to 1820 °C : 1.1 °C |
L | -200.0 °C ~ 900.0 °C | 0.1 °C | -200.0 to 0.0 °C : 0.7 °C 0.0 to 900.0 °C : 0.5 °C |
U | -200.0 °C ~ 600.0 °C | 0.1 °C | -200.0 to 0.0 °C : 0.7 °C 0.0 to 600.0 °C : 0.5 °C |
Thermal resistance RTD | Pt100 385 | -200.0 °C ~ 800.0 °C | 0.1 °C | -200.0 to 0.0 °C : 0.3 °C 0.0 to 400.0 °C : 0.5 °C 400.0 ~ 800.0 °C : 0.8 °C | Adopt ITS-90 temperature scale Pt100 , Cu50 , Cu10 excitation current is: ±0.5~3mA The excitation current is: 0.5 °C additional error when ±0.1~0.5mA Pt200 , Pt500 , Pt1000 excitation current is ±0.05~0.3mA Lead resistance is not included in the accuracy |
Pt200 385 | -200.0 °C ~ 630.0 °C | -200.0 ~ 100.0 °C : 0.8 °C 100.0 ~ 300.0 °C : 0.9 °C 300.0 to 630.0 °C : 1.0 °C |
Pt500 385 | -200.0 °C ~ 630.0 °C | -200.0 ~ 100.0 °C : 0.4 °C 100.0 to 300.0 °C : 0.5 °C 300.0 to 630.0 °C : 0.7 °C |
Pt1000 385 | -200.0 °C ~ 630.0 °C | -200.0 to 100.0 °C : 0.2 °C 100.0 to 300.0 °C : 0.5 °C 300.0 to 630.0 °C : 0.7 °C |
Cu10 | -100.0 °C ~ 260.0 °C | 1.8 °C |
Cu50 | -50.0 °C ~ 150.0 °C | 0.6 °C |
Frequency FREQ | 100Hz | 1.00Hz~110.00Hz | 0.01Hz | ±2 words | 1 to 11 Vp-p square wave level accuracy ±5% reading +0.5V 50% duty cycle Load >100KΩ |
1KHz | 0.100KHz~1.100KHz | 1Hz |
10KHz | 1.0KHz~11.0KHz | 0.1KHz |
100KHz | 10KHz~110KHz | 2KHz | ±5 words |
Pulse PULSE | 100Hz | 1 to 100000cycles | 1cyc | ±2 words | 1 to 11 Vp-p square wave Level accuracy: ±5% reading +0.5V 50% duty cycle load >100KΩ |
1KHz |
10KHz |
Switch SWITCH | 100Hz | 1.00Hz ~ 110.00Hz | 0.01Hz | ±2 words | FET switch Maximum switching current voltage / current: +28 V / 50mA |
1KHz | 0.100KH ~ 1.100KHz | 1Hz |
10KHz | 1.0KHz ~ 11.0KHz | 0.1KHz |
100KHz | 10KHz ~ 110KHz | 2KHz | ±5 words |
Other features of the VICTOR 11+ Process Calibrator :
1. Internal temperature compensation sensor RJC, temperature range 0~50°C, compensation error £ ±0 . 5°C,
2 , temperature probe accuracy: ± 0.2 ° C, probe temperature range: -20 ~ 100 ° C
3 , the maximum voltage is applied between the output terminals and the ground: 30Vp-p
4 , the maximum output current: about 25mA
General characteristics of the VICTOR 11+ process calibrator :
1 working temperature and humidity
0 to 50 ° C, ≤ 80% RH without condensation
40 to 50 ° C, ≤ 70% RH
2 storage temperature and humidity: -25 ~ 60 ° C, ≤ 90% RH without condensation
3 display and backlight
* Segment LCD dual display
* White LED backlight
4 power supply
*4 x 1.5V AAA alkaline battery powered
*CA charger can charge Ni-Hi battery (optional)
* Automatic shutdown operation: can set the automatic shutdown time 0~60 minutes
5 size and weight: 205 × 95 × 42 (mm), about 500g
6 accessories: test pen, fuse