VICTOR Victory VC63 Vibration Meter
Test Range |
Vibration displacement (PP) | 0~1999 μm |
Vibration speed (RMS) | 0~199.9mm/s |
Vibration acceleration (OP) | 0~199.9m/s |
Frequency response range and amplitude error |
Vibration displacement (PP) | 10~200Hz , ≤± 10% |
Vibration speed (RMS) | 10~500Hz , ≤± 10% |
Vibration acceleration (OP) | 10~1000Hz , ≤± 10% |
Amplitude linear error |
Vibration displacement (PP) | 0~20 μm, ≤± 10% |
≥20μm, ≤± 5% |
Vibration speed (RMS) | 0~2.0mm/s , ≤± 10% |
>2.0mm/s, ≤± 5% |
Vibration acceleration (OP) | 0~2.0m/s , ≤± 10% |
>2.0m/s, ≤± 5% |
special function | |
Low voltage display | The battery voltage is lower than 5.5V and the low voltage prompt is displayed. The battery should be replaced at this time. |
Data retention time | When the measurement button is released, the measured data can be held for one minute. |
Indication fluctuation | The indication indicates that the fluctuation is no more than one resolution. |
Ambient temperature | 0~40°C |
Use ambient humidity | ≤80% |
Atmospheric pressure | 75~106kpa |
size | 185 × 68 × 30mm |
weight | 230g ( with battery) |
power supply | 9V (6F22) |
VICTOR Victory VC63A Vibration Meter
Basic function VC63A
1. A complete measurement system can be constructed by simply connecting the sensor;
2. The peak -to- peak value ( PP ) is used to indicate the magnitude of the measured vibration displacement;
3. Use the root mean square value ( RMS ) to indicate the measured vibration velocity;
4 , 3 and a half LCD display;
Basic function 63A
Test Range |
Vibration displacement (PP) | 0~1000 μ m |
Vibration speed (RMS) | 0~71mm/s |
Frequency response range and amplitude error |
Vibration displacement (PP) | 12 ~ 200Hz , ≤ ± 10% |
Vibration speed (RMS) | 12 ~ 500Hz , ≤ ± 10% |
Amplitude linear error |
Vibration displacement (PP) | 0 to 20 μ m , ≤ ± 10% |
> 20 μ m , ≤ ± 5% |
Vibration speed (RMS) | 0 ~ 2mm / s, ≤ ± 10% |
> 2mm / s , ≤ ± 5% |
Note: Low voltage indication: The battery voltage is lower than 6.5V , indicating a low voltage prompt, and the battery should be replaced at this time.
VICTOR Victory VC63B Vibration Meter
Basic function VC63B
Test Range |
Vibration displacement (PP) | 0~1999 μ m |
Vibration speed (RMS) | 0~199.9mm/s |
Vibration acceleration (OP) | 0~199.9m/s^2 |
Frequency response range and amplitude error |
Vibration displacement (PP) | 10~200Hz , ≤± 10% |
Vibration speed (RMS) | 10~500Hz , ≤± 10% |
Vibration acceleration (OP) | 10~1000Hz , ≤± 10% |
Amplitude linear error |
Vibration displacement (PP) | 0~20 μ m , ≤± 10% |
≥ 20 μ m , ≤ ± 5% |
Vibration speed (RMS) | 0~2.0mm/s , ≤± 10% |
> 2.0mm / s , ≤ ± 5% |
Vibration acceleration (OP) | 0~2.0m/s , ≤± 10% |
> 2.0m / s , ≤ ± 5% |
special function | |
Low voltage display | The battery voltage is lower than 5.5V and the low voltage prompt is displayed. The battery should be replaced at this time. |
Data retention time | When the measurement button is released, the measured data can be held for one minute. |
Indication fluctuation | The indication indicates that the fluctuation is no more than one resolution. |
Ambient temperature | 0~40 °C |
Use ambient humidity | ≤ 80% |
Atmospheric pressure | 75~106kpa |
size | 185 × 68 × 30mm |
weight | 300g ( with battery ) |
power supply | 9V (6F22) |