VICTOR Victory VC63 Vibration Meter
| Test Range |
| Vibration displacement (PP) | 0~1999 μm |
| Vibration speed (RMS) | 0~199.9mm/s |
| Vibration acceleration (OP) | 0~199.9m/s |
| Frequency response range and amplitude error |
| Vibration displacement (PP) | 10~200Hz , ≤± 10% |
| Vibration speed (RMS) | 10~500Hz , ≤± 10% |
| Vibration acceleration (OP) | 10~1000Hz , ≤± 10% |
| Amplitude linear error |
| Vibration displacement (PP) | 0~20 μm, ≤± 10% |
| ≥20μm, ≤± 5% |
| Vibration speed (RMS) | 0~2.0mm/s , ≤± 10% |
| >2.0mm/s, ≤± 5% |
| Vibration acceleration (OP) | 0~2.0m/s , ≤± 10% |
| >2.0m/s, ≤± 5% |
| special function | |
| Low voltage display | The battery voltage is lower than 5.5V and the low voltage prompt is displayed. The battery should be replaced at this time. |
| Data retention time | When the measurement button is released, the measured data can be held for one minute. |
| Indication fluctuation | The indication indicates that the fluctuation is no more than one resolution. |
| Ambient temperature | 0~40°C |
| Use ambient humidity | ≤80% |
| Atmospheric pressure | 75~106kpa |
| size | 185 × 68 × 30mm |
| weight | 230g ( with battery) |
| power supply | 9V (6F22) |
VICTOR Victory VC63A Vibration Meter
Basic function VC63A
1. A complete measurement system can be constructed by simply connecting the sensor;
2. The peak -to- peak value ( PP ) is used to indicate the magnitude of the measured vibration displacement;
3. Use the root mean square value ( RMS ) to indicate the measured vibration velocity;
4 , 3 and a half LCD display;
Basic function 63A
| Test Range |
| Vibration displacement (PP) | 0~1000 μ m |
| Vibration speed (RMS) | 0~71mm/s |
| Frequency response range and amplitude error |
| Vibration displacement (PP) | 12 ~ 200Hz , ≤ ± 10% |
| Vibration speed (RMS) | 12 ~ 500Hz , ≤ ± 10% |
| Amplitude linear error |
| Vibration displacement (PP) | 0 to 20 μ m , ≤ ± 10% |
| > 20 μ m , ≤ ± 5% |
| Vibration speed (RMS) | 0 ~ 2mm / s, ≤ ± 10% |
| > 2mm / s , ≤ ± 5% |
Note: Low voltage indication: The battery voltage is lower than 6.5V , indicating a low voltage prompt, and the battery should be replaced at this time.
VICTOR Victory VC63B Vibration Meter
Basic function VC63B
| Test Range |
| Vibration displacement (PP) | 0~1999 μ m |
| Vibration speed (RMS) | 0~199.9mm/s |
| Vibration acceleration (OP) | 0~199.9m/s^2 |
| Frequency response range and amplitude error |
| Vibration displacement (PP) | 10~200Hz , ≤± 10% |
| Vibration speed (RMS) | 10~500Hz , ≤± 10% |
| Vibration acceleration (OP) | 10~1000Hz , ≤± 10% |
| Amplitude linear error |
| Vibration displacement (PP) | 0~20 μ m , ≤± 10% |
| ≥ 20 μ m , ≤ ± 5% |
| Vibration speed (RMS) | 0~2.0mm/s , ≤± 10% |
| > 2.0mm / s , ≤ ± 5% |
| Vibration acceleration (OP) | 0~2.0m/s , ≤± 10% |
| > 2.0m / s , ≤ ± 5% |
| special function | |
| Low voltage display | The battery voltage is lower than 5.5V and the low voltage prompt is displayed. The battery should be replaced at this time. |
| Data retention time | When the measurement button is released, the measured data can be held for one minute. |
| Indication fluctuation | The indication indicates that the fluctuation is no more than one resolution. |
| Ambient temperature | 0~40 °C |
| Use ambient humidity | ≤ 80% |
| Atmospheric pressure | 75~106kpa |
| size | 185 × 68 × 30mm |
| weight | 300g ( with battery ) |
| power supply | 9V (6F22) |