Technical Parameters - user target audience: liquids, gases , and steam
- Supply voltage: 12 ~ 36V DC , standard value 24VDC ;
- output signal: . 4 ~ 20mADC ; ( Special may be four-wire 220V AC power 0-10mA DC output )
- Ambient temperature:- 25 to 70 °C(general transmitter),- 15 to 70 °C(with on-site indicator)
- measure temperature: -40 -104 °C , flange filled with silicone oil -40 -104 °C , filled with high temperature silicone oil 15 -315 °C
- stored temperature:- 40 to 100 °C ;
- Relative temperature: 0-100%RH
- Protection level: d II BT4 , ia II CT5 ;
- Power impact: less than ±0.005%/V of the output range ;
- Vibration effect: Vibrate at 200Hz in any direction , resulting in a maximum range of 0.05% / g(differential pressure 0.25% / g );
- Installation position influence: When the working diaphragm is not installed vertically, it may produce a zero position error of no more than 0.24Pa , the error can be eliminated by adjusting the zero position, and has no effect on the range;
- stability: The accuracy of the transmitter is not exceeded within six months;
- Indicators:Linear indication 0 to 100% ; 3-1/2 digit LCD display
- Range and zero: external continuously adjustable;
- Positive and negative migration: Maximum positive migration is 500% and maximum negative migration is 600%
- materialIsolation diaphragm: 316L Stainless Steel, Alloy H - C , Monel Alloy, Tantalum Exhaust /Drain Valve
: 316L Stainless Steel, Hastelloy- C ,Monel alloy flanges and joints
: 316L Stainless Steel, Ha-Type Alloy- C , Monel Alloy
"O" Ring:Fluorine rubber filling fluid
: Silicone oilInert oil bolts
: 316L Stainless Steel Electronic Housing
: Low copper aluminum alloy
Technical Parameters - user target audience: liquids, gases , and steam
- Supply voltage: 12 ~ 36V DC , standard value 24VDC ;
- output signal: . 4 ~ 20mADC ; ( Special may be four-wire 220V AC power 0-10mA DC output )
- Ambient temperature:- 25 to 70 °C(general transmitter),- 15 to 70 °C(with on-site indicator)
- measure temperature: -40 -104 °C , flange filled with silicone oil -40 -104 °C , filled with high temperature silicone oil 15 -315 °C
- stored temperature:- 40 to 100 °C ;
- Relative temperature: 0-100%RH
- Protection level: d II BT4 , ia II CT5 ;
- Power impact: less than ±0.005%/V of the output range ;
- Vibration effect: Vibrate at 200Hz in any direction , resulting in a maximum range of 0.05% / g(differential pressure 0.25% / g );
- Installation position influence: When the working diaphragm is not installed vertically, it may produce a zero position error of no more than 0.24Pa , the error can be eliminated by adjusting the zero position, and has no effect on the range;
- stability: The accuracy of the transmitter is not exceeded within six months;
- Indicators:Linear indication 0 to 100% ; 3-1/2 digit LCD display
- Range and zero: external continuously adjustable;
- Positive and negative migration: Maximum positive migration is 500% and maximum negative migration is 600%
- materialIsolation diaphragm: 316L Stainless Steel, Alloy H - C , Monel Alloy, Tantalum Exhaust /Drain Valve
: 316L Stainless Steel, Hastelloy- C ,Monel alloy flanges and joints
: 316L Stainless Steel, Ha-Type Alloy- C , Monel Alloy
"O" Ring:Fluorine rubber filling fluid
: Silicone oilInert oil bolts
: 316L Stainless Steel Electronic Housing
: Low copper aluminum alloy
-
-
Van thủy lực Rexroth hydraulic valve 4WE6D62/EG24N9K4, 4WE6Y62/EG24N9K4, 4WE6C62/EG24N9K4 3WE6A62/EG24N9K4, 3WE6B62/EG24N9K4, 4WE6D62/EW230N9K4, 4WE6Y62/EW230N9K4, 4WE6C62/EW230N9K4, 3WE6A62/E
Liên hệ
-
-
Bộ nạp ắcquy, DC screen charging module HYZ22010-5、HYZ22020-5、HYZ22005-5、HYZ11010-5、HYZ11020-5、HYZ11040-5
Liên hệ
-
-
Van điện từ, van khí nén, Airtac three-position solenoid valve 4V330C-10 4V330C-08 DC24V / AC220V
Liên hệ
-
-
Tiếp điểm động+ dây nối MCC, ngắn kéo điều khiển động cơ, GCK, GCS, SYJ-6, SYJ-10, SYJ-16,SYJ-25, SYJ-35, SYJ-50,SYJ-70
Liên hệ
-
-
Đồng hồ đo điện đa năng, VICTOR victory instrument digital multimeter VC99 , VC97
Liên hệ
-
-
cọc tiếp địa, Electrolytic ion ground rod HXFL-530C, HXFL-520C, HXFL-515C
Liên hệ
-
-
Cảm biến áp suất HYDAC EDS 348-5-016-000
Liên hệ
-
-
PROSONIC M FMU40, 41, 42 - CẢM BIẾN MỨC BẰNG SIÊU ÂM
Liên hệ