MI310LTSMI310LTS Infrared Thermometer MI310LTS, American Leitai RAYMI310LTS
The MI3 fixed infrared thermometer includes the following models:
RAYMI302LTS, RAYMI310LTS, RAYMI320LTS, RAYMI310LTF, RAYMI320G5S
RAYMI302LTSCB3, RAYMI302LTSCB8, RAYMI302LTSCB15, RAYMI302LTSCB30
RAYMI310LTSCB3, RAYMI310LTSCB8, RAYMI310LTSCB15, RAYMI310LTSCB30
RAYMI320LTSCB3, RAYMI320LTSCB8, RAYMI320LTSCB15, RAYMI320LTSCB30
RAYMI310LTFCB3, RAYMI310LTFCB8, RAYMI310LTFCB15, RAYMI310LTFCB30
RAYMI320G5SCB3, RAYMI320G5SCB8, RAYMI320G5SCB15, RAYMI320G5SCB30
MI3 Series Communication Box: RAYMI3COMM or RAYMI3MCOMM
The MI3 communication box is a modular system that includes a digital circuit board with an LCD display, buttons and terminals for configuring probe parameters, an IP65 (NEMA 4) compliant metal box (MI3) or a track-type multi-channel probe platform ( MI3M), USB digital communication and a probe with optional optical parameters. Each communication box includes a CD containing the DataTemp Multidrop software and operating manual. Each probe includes a mounting nut and a 1 meter cable. The probe can be ordered separately as a component and communication box.
Standard MI3 Series Sensor Head (Cryogenic Probe):
RAYMI310LTS: Temperature range -40 ~ 600 ° C (-40 ~ 1112 ° F), response wavelength 8 ~ 14 microns, D: S = 10: 1, response time 130ms, 1 meter cable
RAYMI320LTS: Temperature range 0~1000°C (32~18322°F), response wavelength 8~14 microns, D:S=22:1, response time 130ms, 1 meter cable
RAYMI302LTS: Temperature range -40 ~ 600 °C (-40 ~ 1112 °F), response wavelength 8 ~ 14 microns, D: S = 2: 1, response time 130ms, 1 meter cable
Fast MI3 Series Sensor Head (Rapid Response Cryogenic Probe):
RAYMI310LTF: Temperature range 0~1000°C (32~1832°F), response wavelength 8~14 microns, D:S=10:1, response time 20ms, 1 meter cable
MI3 Series Sensor Head (5 micron glass type):
RAYMI320G5S: Temperature range 250~1650°C (482~3002°F), response wavelength 5 microns, D:S=22:1, response time 55ms, 1 meter cable
Sensor head model:
S: The standard probe is resistant to ring temperatures less than 120 ° C (<250 ° F). Only for LT&G5 type
F: The fast response type probe can withstand ring temperature less than 120 ° C (<250 ° F), response time 20 ms (90% energy), only for LT type
Probe cable length option (please specify before ordering)
CB3: 3 m cable (instead of 1 m cable)
CB8: 8 meter cable (instead of 1 meter cable)
CB15: 15m cable (instead of 1m cable)
CB30: 30m cable (instead of 1m cable)
MI3 series communication box
RAYMI3COMM: MI3 series infrared thermometer I/O box with USB2.0 communication. Standard probe models listed above are available
RAYMI3MCOMM: 4-channel infrared temperature measurement system track installation module with USB2.0 and RS485 communication. Standard probe models listed above are available for selection (up to 4 probes are available)
A (communication option): need to explain before ordering
4: RS485 function option for probe configuration, newly added PLC and 0-5V input function, parameter setting and monitoring through half-duplex RS485 interface. Smart RS485 converters for long-range or multi-probe network connections. RS485 interface is standard on RAYMI3MCOMM
System extension attachment
XXXMI3CONNBOX: Multi-channel probe interface box for MI3 and MI3M series communication modules, including 8 parallel terminals, connected to MI3 or MI3M communication module via a 5 meter cable
XXXUSB485: USB to RS232/422/485 converter
RAYMI3COMMI: MI3/MI3M communication box for MI3 probes
Option
XXXMIACMN: probe mounting nut (5)
XXXMIACFB: probe mounting bracket
XXXMIACAB: probe adjustable bracket
XXXMIACAJ: Air Purge (without cooling) for ambient temperatures less than 200 ° C (<392 ° F)
XXXMIACCJ: Air cooling and purging system with 0.8 m insulated air hose for ambient temperatures less than 200 ° C (<392 ° F)
XXXMIACCJ1: Air cooling and purging system with 2.8 m insulated air hose for ambient temperatures less than 200 ° C (<392 ° F)
XXXMIACRAJ1: Right angle mirror with air purge for ambient temperatures less than 200 ° C (<392 ° F)
XXXMIACRAJ: Right-angle mirror with air cooling and purging for ambient temperatures less than 200 ° C (<392 ° F)
XXXMIACPW: MI probe zinc sulfide protection window, not for use in systems with water and air purge
XXXMI3ACPWP: MI3 probe polymer protection window, not for use in systems with water and air purge
XXXMI3ACCFL: MI3 near-focus lens, focal length 10mm, limited to LT type
D82MIACAJ: MI3 stainless steel air purifier (no water), for ambient temperature less than 200C (<392°F)
XXXUSBCABLE: 2-meter 4-core shielded USB cable, one end is a computer USB interface, and the other end is a USB MINI interface