Công ty TNHH công nghệ số Tân Thành

BỘ CHUYỂN ĐỔI NHIỆT ĐỘ ROSEMOUNT 3144P

  • Đăng ngày 18-04-2018 03:57:05 PM - 1573 Lượt xem
  • Mã sản phẩm: 3144P
  • Rosemount 3144P temperature transmitter

    High-performance temperature transmitter is an excellent solution for single-point measurement applications

    The accuracy, stability and reliability of Rosemount 3144P temperature transmitter (equipped with HART or FOUNDATION fieldbus protocol) are at the leading level in the industry. 3144P adopts dual-chamber on-site electromechanical installation configuration, which can prevent water from entering the transmitter and protect the transmitter from electromagnetic surges. The 5-year stability and the optional integrated lightning protection terminal make the 3144P a reliable temperature measuring instrument. Rosemount 3144P is equipped with the function of receiving single sensor and dual sensor input, so it can receive input from two independent sensors at the same time. The dual sensor configuration can be used to balance temperature, measure temperature difference, perform redundant temperature measurement, and use important functions such as hot backup and sensor drift alarm. Users can use advanced diagnostic functions to detect sensor drift, possible thermocouple sensor aging or line interruption, and better monitor programs and equipment.

    • Single sensor and dual sensor input function in one transmitter
    • In process measurement, stable and enhanced EMI elimination and filtering results can be obtained
    • Comply with IEC61508 safety certification third-party verification standard for instrumented safety system (SIS)
    • Industry-leading 5-year stability, reducing maintenance costs
    • Hot Backup® and sensor deviation alarm can gradually improve measurement stability
    • Transmitter-sensor matching technology reduces sensor interchangeability errors and increases accuracy by 75%
    • Dual-chamber enclosure maximizes reliability in harsh environments
    • Integrated LCD meter head with large, easy-to-read display
    • The thermocouple aging diagnosis function allows users to monitor the resistance of the thermocouple circuit to detect sensor failures and perform preventive maintenance in advance to avoid downtime
    • The minimum and maximum temperature tracking function allows users to monitor the temperature of sensor 1, sensor 2 and the difference between the two.

    Tình trạng sản phẩm:


     

      Digital accuracy For Pt100 RTD, ±0.10° C (±0.18° F)
      D/A accuracy The error is ±0.02% (applicable to HART/4-20 mA equipment)
      Ambient temperature influence For Pt100 RTD, for every 1.0 °C (1.8 °F) change in ambient temperature, the error is 0.0015 °C (HART/4-20 mA device error is +0.001%)
      Stability (RTD)

      The reading error within two years is ±0.1% or 0.1°C, whichever is greater
      . The reading error within five years is ±0.25% or 0.25°C, whichever is greater

      enter Two independently configurable inputs; 2, 3 and 4-wire RTD, thermocouple, millivolt and ohm
      Output 4-20 mA/HART or FOUNDATION fieldbus protocol
      Supply voltage 12.0 to 42.4 V dc (with 250 ohm load, 18.1 V dc is required)

       

           

       



      TÂN THÀNH CAM KẾT

      • Sản phẩm, hàng hóa chính hãng.
      • Giá cả cạnh tranh.
      • Dịch vụ chăm sóc khách hàng tận tâm.

      Thông Tin Công Ty

      Đã thông báo

       


      THÔNG TIN LIÊN HỆ:
      -------------------------------
      CÔNG TY TNHH THIẾT BỊ CÔNG NGHIỆP TTH
      Trụ sở: số 124 ngõ 79 Yên Hoà-Cầu giấy-HN
      Kinh doanh 1 : 0816.861.515
      Kinh doanh 2 : 0836.861.515
      Email: tthkinhdoanh@gmail.com
      Email: tthkinhdoanh01@gmail.com

    • Kết nối với chúng tôi