Electrical technical indicators |
Measurement function | Alternating current |
AC current range | 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A |
Range selection | mA / A: Manual selection of 3 mA / 30 mA / 300 mA: automatic selection 3 A / 30 A / 60 A: automatic selection |
Range/resolution | 3 mA1 / 0.001 mA |
30 mA / 0.01 mA |
300 mA / 0.1 mA |
3 A / 0.001 A |
30 A / 0.01 A |
60 A / 0.1 A |
Accuracy – activates the filter (40 to 70 Hz) and turns off the filter (40 to 1 kHz) 2 | 3 mA – 30 A 60 A | 1% + 5 digits 2% + 5 digits |
frequency | 40 Hz to 1 kHz |
Crest factor | ="3" |
After calibration, the accuracy is valid for one year. Accuracy is expressed as ± (% reading + digits) with a reference temperature of 23 ± 5 °C and a maximum relative humidity of 80%. 1 Minimum value is 10 μA true rms value. 2 exceeds TC / °C 18 °C to 28 °C, 0.02 + 1 |
Body characteristics |
Display (LCD) | Digital reading: 3300 words |
Display update rate | 4 times / sec |
Maximum measurable wire diameter | 40mm (F368/368FC); 61 mm (F369/369FC) |
size | 234 x 101 x 46 mm ( F368/368FC) 257 x 116 x 46 mm (F369/369FC) |
weight | 500g (F368/368FC) 600g (F369/369FC) |
battery | 2 AA, IEC LR6, NEDA 15A, alkaline |
Battery Life | Expect battery life to exceed 150 hours without backlights and spotlights |
Automatic shut-down | The clamp will automatically shut down after 15 minutes of inactivity |
Safety and environmental regulations |
General safety | IEC 61010-1: Pollution degree 2 |
Measurement safety | IEC 61010-2-032: CAT III 600 V / CAT IV 300 V |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Working humidity | No condensation (<10 °C) |
90% relative humidity (10 °C to 30 °C) |
75% relative humidity (30 °C to 40 °C) |
45% relative humidity (40 °C to 50 °C) |
Protection level | IEC 60529: IP30 (clamp closure) |
Working elevation | 2000 m |
Storage elevation | 12000 m |
Current sensor action category | IEC 61557-13: Class 1, ≤100 A / m |
Electromagnetic compatibility (EMC) |
International standard |
IEC 61326-1 | Industrial electromagnetic environment |
CISPR 11 | Group 1 Class B |
Group 1 | The RF energy associated with the conducted energy needs to be generated and/or used inside the device, which is essential for the device's own internal functions. |
Class B | The device is suitable for use in household appliances as well as any device that is directly connected to a low voltage network that powers residential buildings. When this equipment is connected to a test target, it may exceed the emission level specified in CISPR 11 requirements. Korea (KCC): Class A equipment (industrial broadcasting and communication equipment) |
Class A | This product meets the requirements of industrial electromagnetic equipment, and should be noted by the seller or user. This equipment is designed for use in a commercial environment, not a residential environment. USA (FCC): 47 CFR Part 15 B. This product is considered to be a tax-free device in accordance with Section 15.103. |