Trang nhất
Dụng cụ cầm tay, dụng cụ toolFluke
Ampe kìm phân tích công suất, Fluke FLUKE345 power quality analyzer F345 tester FLUKE353/F355 clamp meter
Đăng ngày 09-11-2018 12:05:53 AM - 600 Lượt xem
Mã sản phẩm: FLUKE353/F355
Fluke 345 Handheld Harmonic Clamp Meter
This power quality clamp meter combines the power of a power analyzer, power quality recorder and clamp meter to provide an ideal tool for monitoring electrical loads.
Thanks to the high-brightness color energy detector display for analyzing the harmonic spectrum, the low-pass filter for filtering high-frequency signal and noise, and the excellent electromagnetic anti-jamming design, the Fluke 345 energy analyzer is very suitable for maintenance and variable. The power quality of the load is faulty. In addition, with the energy meter, the Hall effect clamp meter can also measure DC current without interrupting the circuit.The built-in memory of the Power Analyzer allows users to record power quality parameters over long periods of time to analyze trends or intermittent problems.
Fluke 345 finished product application - Set up and troubleshoot variable frequency motors and UPS systems – check for normal power quality parameters to verify proper operation
- Harmonic Measurements – Finding harmonic problems that can damage or destroy critical equipment
- Inrush current capture – check for startup current when a suspected restart or annoying circuit trip occurs
- Load Analysis – Verify the capacity of the power system before adding load
| Features - AC/DC current: AC current (up to 1400 A) and DC current (up to 2000 A) without shutting down the circuit
- Meets the highest safety standards: 600 V CAT IV energy analyzer can be used at the inlet
- Accurate measurement in a signal-to-noise environment: Thanks to a low-pass filter, the clamp meter can make accurate measurements even if there is a distorted waveform in the electrical load
- Data logging: Any power quality parameter (including harmonics) can be recorded for a few minutes or even more than one month to detect intermittent faults
- Verify the battery: directly measure the DC fluctuation of the battery and DC system (%)
- Eliminate harmonic faults: Analyze and record harmonics in digital or graphical form
- Inrush current: capture and analyze annoying current fluctuations (3 seconds to 300 seconds)
- Easy to use: Wide backlit display for waveforms and trends for easy confirmation of power meter settings
- Three-phase power: built-in balanced load function
- View graphs and generate reports: Use the power analyzer with the included power logging software
|
Technical Parameters display |
| Color see-through LCD, 320 x 240 pixels (70 mm diagonal), 2 levels of backlight | | |
power supply |
| | Battery type: 1.5 V AA alkaline battery, MN 1500 or IEC LR6 x 6 | |
Battery life (typical) | | > 10 hours (full backlight) | | > 12 hours (limited backlight) | |
AC adapter box BE345 | Input | 110/230 V 50/60 Hz | Output | 15 V dc, 300 mA | |
Environmental conditions (indoor use only) |
Reference condition | | All accuracy is measured in an environment of 23 ° C ± 1 ° C (73.4 ° F ± 1.8 ° F) | |
Operating temperature | | 0°C to 50°C (32°F to 122°F) | |
Temperature coefficient of current | |
Temperature coefficient of voltage | |
Maximum relative humidity | | 80% at temperatures not exceeding 31°C (87°F) and 50% at 40°C (104°F) | |
Maximum operating altitude | |
Electrical Safety |
| | IEC 61010-1 600 V CAT IV, double or reinforced insulation, Class 2 pollution protection | |
| | Protection class IP40; EN60529 | |
Highest safe working voltage | Current measurement | Between non-insulated conductor and ground wire: 600 V ac rms or dc | Voltage measurement | Between the input terminal and the ground wire: 600 V ac rms or dc; between the excitation phase voltages (triangular power supply configuration) 825 V | |
EMC |
Radiation | | IEC/EN 61326-1:1997 Class A | |
Electromagnetic interference prevention | | IEC/EN 61326-1:1997 Appendix C, Performance Standards B | |
Mechanical technical index |
Dimensions (length x width x height) | | 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) | |
Weight (including battery) | |
Jaw | |
Jaw capacity | |
clean | | The device can be cleaned with a soft cloth soaked in isopropyl alcohol. Do not use abrasives or other solvents. | |
Current measurement (dc, dc rms, ac rms) |
Range | | 0 to 2000 A dc or 1400 ac rms | |
Automatic range adjustment | |
Resolution | | 10 mA (40 A range) | | 100 mA (400 A range) | | 1 A (2000 A range) | |
Accuracy: dc and dc rms | I > 10 A: | ± 1.5 % reading ± 5 digits | I < 10 A: | ± 0.2 A | |
Accuracy: AVG | I > 10 A: | ± 3 % reading ± 5 digits | I < 10 A: | ± 0.5 A | |
Accuracy: Pk | I > 10 A: | ± 5 % reading ± 5 digits | I < 10 A: | ± 0.5 A | |
Accuracy: AHr | I > 10 A: | ± 2 % reading ± 5 digits | I < 10 A: | ± 0.5 AHr | |
Accuracy: CF (peak factor) | 1.1 ≤ CF < 3: | ± 3 % reading ± 5 digits | 3 ≤ CF < 5: | ± 5 % reading ± 5 digits | Resolution: | 0.01 | |
Accuracy: RPL (fluctuation) | 2 % ≤ RPL < 100 %: | ± 3 % reading ± 5 digits | 100 % ≤ RPL < 600 %: | ± 5 % reading ± 5 digits | Resolution: | 0.1 % | Idc > 5 A, Iac > 2 A | | |
Voltage measurement (dc, dc rms, ac rms) |
Range | |
Automatic range adjustment | | 4 V / 40 V / 400 V / 750 V | |
Resolution | | 1 mV (4 V range) | | 10 mV (40 V range) | | 100 mV (400 V range) | | 1 V (750 V range) | |
Accuracy: dc and dc rms | V > 1 V: | ± 1 % reading ± 5 digits | V < 1 V: | ± 0.02 V | |
Accuracy: AVG | V > 1 V: | ± 3 % reading ± 5 digits | V < 1 V: | ± 0.03 V | |
Accuracy: Pk | V > 1 V: | ± 5 % reading ± 5 digits | V < 1 V: | ± 0.03 V | |
Accuracy: CF (peak factor) | 1.1 ≤ CF < 3: | ± 3 % reading ± 5 digits | 3 ≤ CF < 5: | ± 5 % reading ± 5 digits | Resolution: | 0.01 | |
Accuracy: RPL (fluctuation) | 2 % ≤ RPL < 100 %: | ± 3 % reading ± 5 digits | 100 % ≤ RPL < 600 %: | ± 5 % reading ± 5 digits | Resolution: | 0.1 % | Vdc > 0.5 V, Vac > 0.2 V | | |
| | Both are DC measurements, 15 Hz to 1 kHz maximum overload 1,000 V rms voltage rms is true rms measurement (ac + dc) | |
harmonic |
THD (total harmonic distortion) | 1 % ≤ THD < 100 %: | ± 3 % reading ± 5 digits | 100 % ≤ THD < 600 %: | ± 5 % reading ± 5 digits | Resolution: | 0.1 % | |
DF (distortion coefficient) | 1 % ≤ DF < 100 %: | ± 3 % reading ± 5 digits | Resolution: | 0.1 % | H02 ≤ Vharm < H13: | ± 5 % ± 2 digits | H13 ≤ Vharm ≤ H30: | ± 10 % ± 2 digits | |
| | All measurements up to the 30th harmonic (40th harmonic for 15 Hz to 22 Hz) fundamental frequency range: F 0 15 Hz to 22 Hz and 45 Hz to 65 Hz Vacrms > 1V | |
Power measurement (single and three phase) (dc, dc rms, ac rms) |
Range | | 0 to 1650 kW dc or 1200 kW ac | |
Automatic range adjustment | | 4 kW, 40 kW, 400 kW, 1650 kW | |
Resolution | | 1 W (4 kW range) | | 10 W (40 kW range) | | 100 W (400 kW range) | | 1 kW (1200 kW range) | |
Accuracy | | 2.5 % reading ± 5 digits | | W1Ø < 2 kW ± 0.08 kW | | W3Ø < 4 kW ± 0.25 kW | |
VA measurement (single phase and three phase) (dc, dc rms, ac rms) |
Range | | 0 to 1650 kVA dc or 1200 kVA ac | |
Automatic range adjustment | | 4 kVA, 40 kVA, 400 kVA, 1650 kVA | |
Resolution | | 1 VA (4 kVA range) | | 10 VA (40 kVA range) | | 100 VA (400 kVA range) | | 1 kVA (1200 kVA range) | |
Accuracy | VA > 2 kVA: | 2.5 % reading ± 5 digits | VA < 2 kVA: | ± 0.08 kVA | |
VAR measurement (single and three phase) |
Range | |
Automatic range adjustment | | 4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR | |
Resolution | | 1 VAR (4 kVAR range) | | 10 VAR (40 kVAR range) | | 100 VAR (400 kVAR range) | | 1 kVAR (1200 kVAR range) | |
Accuracy | VAR > 4 kVAR: | ± 2.5 % of reading ± 5 digits | VAR < 4 kVAR: | ± 0.25 kVAR | |
Power factor range | |
Power factor (single phase and three phase) |
Range | | 0.3 (capacitive) to 1.0 and 1.0 to 0.3 (inductive) (72.5° (capacitive) to 0° and 0° to 72.5° (inductive)) | |
Resolution | |
Accuracy | |
Frequency Range | |
Offset power factor (single phase and three phase) |
Range | | 0.3 (capacitive) to 1.0 and 1.0 to 0.3 (inductive) (72.5° (capacitive) to 0° and 0° to 72.5° (inductive)) | |
Resolution | |
Accuracy | |
Frequency Range | | 15 Hz to 22 Hz and 45 Hz to 65 Hz | |
Kilowatt hours (kWHr) |
Range | |
Automatic range adjustment | | 4 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr | |
Resolution | | 1 WHr (4 kWHr range) | | 10 WHr (40 kWHr range) | | 100 WHr (400 kWHr range) | | 1 kWHr (4,000 kWHr range) | | 10 kWHr (40,000 kWHr range) | |
Accuracy | kWHr > 2 kWHr: | ± 3 % ± 5 digits | kWHr < 2 kWHr: | ± 0.08 kWHr | |
All power / VA / VAR / PF measurements | Frequency Range: | DC, 15 Hz to 1 kHz | Current range: | 10 A to 1400 A rms | voltage range: | 1 V to 825 V rms | Maximum input: | 825 V rms/1400 A rms | Maximum overload: | 1000 V rms/10,000 A; both DC measurements, 15 Hz to 1 kHz.Maximum overload 10,000 A or true rms x frequency < 400,000 | |
Frequency measurement (current or voltage source) |
Range | |
Resolution | |
Accuracy | | 15 to 22 Hz ± 0.5 % reading | | 40 to 70 Hz ± 0.5 % reading | | 15 to 1000 Hz ± 1 % reading | |
Current range | |
voltage range | |
Range function |
Current measurement | Range: | 10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A | Resolution: | 1 A (40 A range) 10 A (400 A range) 50 A (2000 A range) | Accuracy: | ± 3 % reading ± 1 pixel | Maximum overload: | 10,000 A | |
Voltage measurement | Range: | 4 V / 10 V / 20 V / 40 V / 100 V / 200 V / 400 V / 1000 V | Resolution: | 100 mV (4 V range) 1 V (40 V range) 10 V (400 V range) 31.25 V (1000 V range) | Accuracy: | ± 2 % reading ± 1 pixel | Maximum overload: | 1000 V rms | Frequency Range: | DC, 15 Hz to 600 kHz | |
Time base | | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div | |
Refresh rate | |
Highest sampling rate | |
Inrush current function |
Range | |
Resolution | | 10 mA (40 A range) | | 100 mA (400 A range) | | 1 A (2000 A range) | |
Accuracy | I > 10 A: | ± 5 % reading ± 1 pixel | I < 10 A: | ± 0.5 A | | Both are DC measurements, 15 Hz to 1 kHz | |
Maximum overload | | Maximum overload 10,000 A or true rms x frequency < 400,000 | | Current rms is true rms measurement (ac + dc) | |
Capture time | | 1 s, 3 s, 10 s, 30 s, 100 s, and 300 s | |
Highest sampling rate | |
interface |
| | Connect to the PC's USB interface | |
| | Power recording software for downloading, analysis and reporting | |
| | 345 upgrade utility for installing new firmware versions | |
Record memory |
Recording area | | Three zones that can be used individually or combined into one larger zone | |
Average period | | 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min and custom | |
Model Name | description |
Fluke 345 | The power quality clamp meter contains: - 345 power quality clamp meter
- Soft carrying case
- Power recording software
- Test line
- Crocodile clip
- Test probe
- USB cable
- International AC adapter/transfer box
- English printing user manual
- Multi-language manual CD
| |
Fluke 355/353 2000A True RMS Clamp Meter
Rugged, versatile tool for high current applicationsFluke 355 and 353 digital clamps give users confidence to read reliable true rms readings; ideal current clamps for high currents up to 2000A. Ultra-wide jaws make it easy to grip thick wires that are common in high current applications.Ultra-durable design and CAT IV 600 V, CAT III 1000 V safety certification provide a higher level of user safety for high energy measurements.
The inrush current mode allows accurate peak measurements and is therefore ideal for motors and inductive loads. The Model 355 also measures voltage and resistance and is the ideal clamp for engineering, electrical contractors and industrial maintenance electricians. Features - Reliably handle a wide range of high current applications with measurement ranges up to 2000 A ac + dc true rms, 1400 A ac and 2000 A dc
- Large 58 mm (2.3 in) jaw for measuring current in thick or multiple wires
- CAT IV 600 V, CAT III 1000 V safety certification, increased user safety level
- Inrush current measurement can accurately capture 'boot' surge current
- Up to 1000 V ac + dc True RMS, 600 V ac and 1000 V dc high voltage measurement range, allowing users to perform multiple tests with just one tool (355 models only)
- The combination of up to 400K ohms and on-off buzzer makes the meter more convenient for multimeters. (355 type only)
- Accurate measurement of frequencies up to 1 kHz, ideal for service applications
- Quickly analyze readings using the min, max, and average functions
- Large, backlit display makes it easy to view in low-light areas
- Use the display hold feature to capture readings even when the display cannot be viewed
- Use a low pass filter to eliminate noise loads and stabilize readings
| |
Technical Parameters Electrical technical indicators |
Current measurement: dc and ac, 10 Hz to 100 Hz | Range : 40A | Resolution : 10 mA Class A Accuracy : 1.5 % Reading + 15 digits Inrush Current Trigger Level : 0.50 A Trigger Level of Frequency Filter Off : 2.50 A Trigger Level of Frequency Filter On : 0.50 A | Range : 400A | Resolution : 100 mA Class A Accuracy : 1.5 % Reading + 5 digits Inrush Current Trigger Level : 5.0 A Frequency Filter Off Trigger Level : 2.5 A Frequency Filter On Trigger Level : 2.5 A | Range : 2000 A; 1400 ac rms | Resolution : 1 A Class A Accuracy : 1.5 % Reading + 5 digits Inrush Current Trigger Level : 5 A Trigger Level of Frequency Filter Off : 8 A Trigger Level of Frequency Filter On : 8 A | |
Crest factor (50/60 Hz) | Range : 40A | Crest factor * : 2 @ 33 A, 2.4 @ 27 A | Range : 400A | Peak Factor* : 2 @ 330 A, 2.4 @ 270 A | Range : 2000 A; 1400 ac rms | Crest factor * : 2 @ 1000 A, 2.4 @ 833 A | |
Current measurement : ac, 100.1 Hz to 1 kHz | Range : 40A | Resolution : 10 mA Accuracy > 10 A : 3.5 % Reading + 15 digits Inrush Current Trigger Level : 0.50 A Trigger Level of Frequency Filter Off : 2.50 A Trigger Level of Frequency Filter On : 0.50 A | Range : 400A | Resolution : 100 mA Accuracy > 10 A : 3.5 % Reading + 5-digit Inrush Current Trigger Level : 5.0 A Frequency Filter Off Trigger Level : 2.5 A Frequency Filter On Trigger Level : 2.5 A | Range : 2000 A; 1400 ac rms | Resolution : 1 mA Accuracy > 10 A : 3.5 % Reading + 5-digit Inrush Current Trigger Level : 5 A Trigger Level of Frequency Filter Off : 8 A Trigger Level of Frequency Filter On : 8 A | |
Voltage measurement : (type 355 only) dc and ac, 10 Hz to 100 Hz (600 V and 1000 V range over 10 %, up to 660 V and 1100 V respectively) | Range : 4 V | Resolution : 1 mV Accuracy : 1 % Reading + 10-bit digital frequency filter off trigger level : 0.050 V frequency filter on trigger level : 0.050 V | Range : 40 V | Resolution : 10 mV Accuracy : 1 % Reading + 5-bit digital frequency filter off trigger level : 0.25 V frequency filter on trigger level : 0.25 V | Range : 400 V | Resolution : 100 mV Accuracy : 1 % Reading + 5-bit digital frequency filter off trigger level : 6 V frequency filter on trigger level : 6 V | Range : 600 V ac rms | Resolution : 1 mV Accuracy : 1 % Reading + 5-bit digital frequency filter off trigger level : 6 V frequency filter on trigger level : 6 V | Range : 1000 V dc | Resolution : 1 V Accuracy : 1 % reading + 5 digits | |
Voltage measurement : (type 355 only) ac, 100.1 Hz to 1 Hz (600 V and 1000 V range over 10 %, up to 660 V and 1100 V respectively) | Range : 4 V | Resolution : 1 mV Accuracy : 3 % Reading + 10-bit digital frequency filter off trigger level : 0.050 V frequency filter on trigger level : 0.050 V | Range : 40 V | Resolution : 10 mV Accuracy : 3 % Reading + 5-bit digital frequency filter off trigger level : 0.25 V frequency filter on trigger level : 0.25 V | Range : 400 V | Resolution : 100 mV Accuracy : 3 % Reading + 5-bit digital frequency filter off trigger level : 6 V frequency filter on trigger level : 6 V | Range : 600 V ac rms | Resolution : 1 V Accuracy : 3 % Reading + 5-bit digital frequency filter off trigger level : 6 V frequency filter on trigger level : 6 V | |
Resistance measurement (type 355 only) | Range : 400 Ω | Resolution : 0.1 Ω Accuracy : 1.5 % + 5 digits | Range : 4 kΩ | Resolution : 1 Ω Accuracy : 1.5 % + 5 digits | Range : 40 kΩ | Resolution : 10 Ω Accuracy : 1.5 % + 5 digits | Range : 400 kΩ | Resolution : 100 Ω Accuracy : 1.5 % + 5 digits | |
On-off buzzer (type 355 only) | |
Measuring frequency | Measuring range | 5.0 Hz to 1 kHz | Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 digits | Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 digits | Trigger level | Reference current and voltmeter | |
General technical indicators |
battery | | Six 1.5 AA (NEDA 15A or IEC LR6) | |
Battery life (typical use, backlight off) | |
Test line | |
weight | |
Jaw size | |
Dimensions (length x width x thickness) | | 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) | |
Security Level | | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III | |
Environmental technical indicators |
Operating temperature | | 32 °F to +122 °F (0°C to +50°C) | |
Storage temperature | | -4 °F to +140 °F (-20 ° C to +60 ° C) | |
Operating humidity | | 0 to 95% (no condensation) | |
Operating altitude | |
Storage altitude | |
IP rating | |
Drop test requirement | |
EMI, RFI, EMC | | FCC part 15, IEC/EN 61326-1:1997 Class B, IEC/EN 61326:1997 3V/m, performance standard B, EN61325 | |
Temperature Coefficient | Current : | 0.1% of reading (per °C, outdoor, 22 °C to 24 °C) | Voltage : | 0.1% of reading (per °C, outdoor, 22 °C to 24 °C) | |
Model Name | description |
Fluke 355 | AC/DC True RMS Clamp Meter, 2000A includes: - 355 clamp table
- C43 soft carrying case
- 6 AA batteries
- TL224 1.5 m silicone rubber test line
- TP2 test probe
- AC285 Alligator Clip
- User manual
- 3 year warranty
|
Fluke 353 | AC/DC True RMS Clamp Meter, 2000A, Test Current Only Includes: - 353 clamp table
- C43 soft carrying case
- 6 AA batteries
- User manual
- 3 year warranty
|
-
-
Thiết bị hiệu chuẩn dòng điện, điện áp FLUKE , Fluke F705/F707/F715/F709/F709H, Calibrator FLUKE715 Voltage Current Calibrator
Liên hệ
-
-
Máy hiệu chuẩn áp suất Fluke, Fluke F717/F718/F719/F719Pro, pressure calibrator FLUKE718/719 pressure calibrator
Liên hệ
-
-
ĐỒNG HỒ ĐO ĐIỆN CHỈ THỊ PHA, Fluke F9040 phase sequence indicator ,F9062 motor phase sequence indicator FLUKE2042 cable tester
Liên hệ
-
-
Súng đo nhiệt độ bằng hồng ngoại ,FLUKE F572/F574, infrared thermometer ,FLUKE574 thermometer -30-900 °C
Liên hệ
-
-
Súng đo nhiệt độ bằng hồng ngoại ,Fluke F59/F59E/MT4MAX/MT4MAX+/F62MAX/F62MAX+/ST20MAX Thermometer Kit
Liên hệ
-
-
Thiết bị đo nhiệt độ tiếp xúc, FLUKE F51-II/F52-II/F53-IIB/F54-IIB, thermometer F52-2/F53-2B/F54-2B
Liên hệ
-
-
Ampe kìm đo dòng nhỏ,Fluke F342/LH41A small current clamp meter FLUKE342 clamp meter F902FC clamp meter F360
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke F353/F355 Clamp Meter FLUKE353/FLUKE355, Clamp Meter High Current 2000A
Liên hệ
-
-
Ampe kìm đo dòng rò, Fluke F368 F368FC F369 F369FC, leakage current clamp table ,FLUKE368FC FLUKE369FC
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke F323/F324/F325 Clamp Meter
Liên hệ
-
-
Thiết bị kiểm tra điện áp, Fluke FLUKE T6-600/T6-1000, non-contact voltage clamp meter, T5-600/T5-1000 voltage clamp
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke FLUKE373/F374FC/F375FC/F376FC, FLUKE381/FLUKE376
Liên hệ